Professor Advisordc.contributor.advisorVargas Sanhueza, Verónica es_CL
Authordc.contributor.authorAdasme Jeria, Rodrigo es_CL
Authordc.contributor.authorNazal Lama, Catalina 
Staff editordc.contributor.editorFacultad de Medicinaes_CL
Staff editordc.contributor.editorEscuela de Kinesiologíaes_CL
Associate professordc.contributor.otherOrtiz Zúñiga, Sylvia 
Associate professordc.contributor.otherGonzález Banderas, Carolina
Associate professordc.contributor.otherAravena Ramírez, Patricio
Admission datedc.date.accessioned2012-09-12T19:18:40Z
Available datedc.date.available2012-09-12T19:18:40Z
Publication datedc.date.issued2003es_CL
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/110581
Abstractdc.description.abstractEl presente estudio descriptivo transversal tiene por objetivo determinar el cumplimiento de las recomendaciones de emisión de ondas electromagnéticas en equipos de onda corta terapéutica (27,12 MHz) de los servicios de salud pública de la región metropolitana durante el año 2003. Se midió y registró la intensidad de campo eléctrico (V/Mt) en el campo cercano (1 metro del foco) en la población de equipos de onda corta en funcionamiento (N = 47) en los hospitales públicos, Centros de Referencia de Salud (CRS) y Centros de Diagnóstico y Tratamiento (CDT), utilizando el detector Wandel y Goltermann EMR 30, sonda 8 perteneciente al Instituto de Salud Pública. Los resultados obtenidos indicaron que el 100% (n = 34) de los equipos del Área Norte, Centro, Sur, Sur-Oriente y Occidente cumplen con la recomendación internacional de la ICNIRP (International Commission on Non-ionizing Radiation Protection) a nivel ocupacional (61 V/Mt). En el área Oriente, la recomendación se cumple en el 92,3% (n = 13) de los equipos. En el total de equipos de la Región Metropolitana (N = 47), el 97,87% (n = 46) cumple con la recomendación ICNIRP de intensidad de campo eléctrico (Nivel de Confianza 95%).
Abstractdc.description.abstractThe objective of this traverse descriptive study is to stablish the fulfillment of recommendations of electromagnetic waves emissions in short wave equipments of the Public Health Services of the Metropolitan Region during 2003. We measure the electric field intensity (V/Mt) on the near field (1 meter from the focus) in operative population of short wave equipments (N = 47) inside Public Hospitals, Health Reference Centers (CRS) and Diagnose and Treatment Centers (CDT) using the electromagnetic measurement equipment Wandel y Goltermann EMR 30, sound type 8, of the Public Health Institute. The results shows that 100% (n = 34) of the equipments in the North, Center, South, South-Orient and Occident Areas fulfill the international occupational recommendation ( 61 V/Mt) of ICNIRP (International Commission on Non-ionizing Radiation Protection). In the Orient Area the recommendation is fulfilled on the 92,3% (n = 13) of equipments. In the Metropolitan Region total equipments (N = 47) the 97,87% (n = 46) fulfill the recommendation (Confidence Level 95%).
Lenguagedc.language.isoeses_CL
Publisherdc.publisherUniversidad de Chilees_CL
Type of licensedc.rightsAdasme Jeria, Rodrigo ; Nazal Lama; Catalinaes_CL
Keywordsdc.subjectKinesiologíaes_CL
Keywordsdc.subjectOndas electromagnéticases_CL
Keywordsdc.subjectes_CL
Keywordsdc.subjectes_CL
Keywordsdc.subjectSalud pública--Chilees_CL
Títulodc.titleMedición de la intensidad de campo eléctrico de los equipos de onda corta en uso en los Servicios de Salud Pública Metropolitana de Kinesiología y Medicina Física y Rehabilitación el año 2003 y determinación del cumplimiento de la recomendación ICNIRP ocupacionales_CL