Show simple item record

Authordc.contributor.authorKracht Gajardo, Willy 
Authordc.contributor.authorHunt, C. 
Admission datedc.date.accessioned2016-10-18T20:20:08Z
Available datedc.date.available2016-10-18T20:20:08Z
Publication datedc.date.issued2016
Cita de ítemdc.identifier.citationMinerals Engineering 92 (2016) 110–113es_ES
Identifierdc.identifier.other10.1016/j.mineng.2016.03.010
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/140866
Abstractdc.description.abstractThe local critical coalescence concentration l-CCC presents a relationship between frother concentration and the gas flow rate Q(g)' at which coalescence starts to occur at a capillary tube. Such a relationship is used in this work to determine frother concentration. The solution with unknown frother concentration is tested to determine Qg' and the concentration is determined from a reference l-CCC curve that has been previously determined for the frother to be tested. The technique is simple, and easy to implement. The determination of the reference l-CCC curve takes 1 h or less, after which the measurements are very quick, taking no more than 5 min per sample. The technique was validated against the total organic carbon (TOC) method for a series of samples of unknown frother concentration, for three different frothers, with a correlation coefficient R-2 equal to 0.997. The measurements are not affected by the presence of xanthate in the system, when using MIBC as a frother, which suggests the possibility of using it, combined with TOC analysis to determine both frother and xanthate concentration by mass balancing.es_ES
Patrocinadordc.description.sponsorshipChilean National Commission for Scientific and Technological Research (CONICYT) through the National Fund for Scientific and Technological Development (FONDECYT) project 1110173 Octave development communityes_ES
Lenguagedc.language.isoenes_ES
Publisherdc.publisherElsevieres_ES
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile*
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/*
Sourcedc.sourceMinerals Engineeringes_ES
Keywordsdc.subjectFrother concentrationes_ES
Keywordsdc.subjectFlotationes_ES
Keywordsdc.subjectCoalescencees_ES
Títulodc.titleIndirect measurement of frother concentration based on l-CCC curveses_ES
Document typedc.typeArtículo de revista
Catalogueruchile.catalogadorlajes_ES
Indexationuchile.indexArtículo de publicación ISIes_ES


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Chile
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile