Show simple item record

Professor Advisordc.contributor.advisorMoreno Vieyra, Rodrigo
Authordc.contributor.authorGonzález Venegas, Felipe Héctor Nicolás 
Associate professordc.contributor.otherVargas Díaz, Luis
Associate professordc.contributor.otherBarroso, Luiz
Admission datedc.date.accessioned2016-12-06T14:01:33Z
Available datedc.date.available2016-12-06T14:01:33Z
Publication datedc.date.issued2016
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/141683
General notedc.descriptionMagíster en Ciencias de la Ingeniería, Mención Eléctrica. Ingeniero Civil Eléctricoes_ES
Abstractdc.description.abstractImportar gas natural licuado (GNL) a través de contratos Take-or-Pay (ToP) para la generación de electricidad en sistemas hidrotérmicos es una tarea compleja ya que la demanda de gas es altamente incierta dada la variabilidad de las condiciones hídricas. Esto es agravado por la dificultad de transar ex-post los excedentes/déficits de GNL en un mercado secundario (p. ej. cuando el GNL importado no basta para satisfacer la demanda en condiciones hídricas húmedas), el cual es, muchas veces, muy reducido. En este contexto, la presente tesis propone un modelo de optimización estocástica de minimización de costos y aversión al riesgo que permite determinar portafolios óptimos de contratos de suministro de GNL para el sistema eléctrico nacional (desde la perspectiva del planificador social). Este portafolio incluye contratos con varios grados de flexibilidad e interacciones con el mercado spot. A través de varios casos de estudio basados en el principal Sistema eléctrico Chileno (SIC) se conluyó lo siguiente: (i) es óptimo, desde una perspectiva neutral al riesgo, importar GNL para una condición hídrica promedio . Esto implica que el GNL contratado (a través de contratos ToP) no será suficiente en condiciones hídricas secas donde se necesitarán centrales más costosas (p. ej. unidades diésel) para suplir la demanda eléctrica, mientras que en condiciones húmedas las centrales a gas desplazarán generación menos costosa (p. ej. unidades a carbón). (ii) es óptimo, desde una perspectiva de aversión al riesgo, importar GNL para una condición hídrica seca . Esto implica que el planificador social aumentará las importaciones de GNL para proteger al sistema de sobrecostos operacionales en condiciones secas. Esta decisión sistémica es fundamentalmente diferente a la tomada por compañías de generación en un ambiente de mercado, quienes se protegen del riesgo disminuyendo las importaciones de GNL. (iii) contratos ToP con cláusulas flexibles pueden soportar un aumento en los volúmenes importados de GNL acompañado de una reducción de costos operacionales del sistema. (iv) los requerimientos óptimos de GNL para el SIC son cercanos a 6 TWh por año, lo cual es casi el doble de los 3.47 TWh que se importan actualmente. Este monto (6 TWh) puede aumentarse si (i) el planificador social fuera averso al riesgo, protegiendo a los consumidores de sobrecostos producidos por sequías, y/o (ii) se modelaran contratos más flexibles. (v) aumentar los volúmenes importados de GNL a 6 TWh por año (desde los 3.47 TWh actuales) disminuirá los costos esperados del sistema en un 4.1% y reducirá los pagos de la demanda en un 32.1%. Esta reducción desproporcionada en los pagos de la demanda es debido a que parte del excedente del productor es transferido al consumidor gracias a una disminución de los costos marginales del sistema. (vi) es posible diseñar un mecanismo de pago (i.e. price uplifts) donde la demanda cubra parcialmente los costos fijos de los generadores (cuando los precios spot no cubran los costos de GNL) de manera de compartir eficientemente entre el riesgo generadores y demanda. Esto sería beneficioso para ambos ya que estarían en una mejor posición económica que la actual. A pesar que los casos de estudio están enfocados en el mercado chileno, creemos que esto es de interés para otros sistemas hidrotérmicos de América Latina y África, que enfrentan (o lo harán en el futuro cercano) problemas similares asociados al suministro de GNL. Por lo tanto esta investigación puede ser crítica para entender los costos y beneficios de las decisiones relacionadas con la importación de GNL y, de esta manera, sostener un desarrollo y una operación de sistemas eléctricos más eficiente y segura. Este trabajo es, a su vez, oportuno y puede servir para aprovechar los bajos precios en el mercado internacional del GNL que se observan actualmente.es_ES
Abstractdc.description.abstractImporting liquefied natural gas (LNG) through take-or-pay (ToP) contracts for electricity generation is significantly challenging in hydrothermal systems since gas demand from the electricity sector is highly uncertain due to the historical volatile behavior associated with hydro conditions. This is compounded by the difficulties to undertake ex-post trading of surpluses/shortfalls of LNG in a secondary market (e.g. when LNG imported does not suffice during dryer hydro conditions), which is –in many cases– significantly limited. In this context, this thesis proposes a cost-minimization, risk-averse stochastic optimization model that allows us to find optimum portfolios of LNG supply contracts for the national power system (from the social planner’s perspective). This portfolio includes contracts with various degrees of flexibility and interactions with the spot market. Through several case studies based on the Chilean power system, we found that: (i) it is optimal, from a risk-neutral, cost-minimization perspective, to import natural gas for an “average” hydro condition. This implies that contracted natural gas (through ToP contracts) will not suffice under dryer conditions where more costly plants (e.g. diesel units) will be needed to supply electricity demand and that gas plants will displace less costly plants (e.g. coal units) during wetter hydro conditions. (ii) it is optimal, from a risk-averse, cost-minimization perspective, to import natural gas for a “dryer” hydro condition. This implies that a social planner will increase LNG imports in order to hedge the system against operational cost spikes during dry conditions. This system-wide decision is fundamentally different to that taken in a market environment where generation companies (e.g. gas plant owners) tend to hedge risk exposure by under-importing LNG. (iii) flexible clauses in ToP contracts can support increased LNG import volumes and a reduction in system operating costs. (iv) optimal LNG system requirements for the Chilean main electricity system are circa 6 TWh per year which is almost twice the amount of 3.47 TWh that is currently being imported. This amount (6 TWh per year) can be increased if (i) the social planner were risk averse to protect consumers against higher costs driven by droughts, and/or (ii) more flexible contracts are modelled. (v) increasing the import volumes to 6 TWh per year (from current 3.47 TWh) will decrease expected system costs by 4.1% and reduce demand payments by 32.1%. This disproportional reduction in demand payments is observed since part of producer’s surplus is transferred to the consumer’s surplus as system marginal costs decrease. (vi) it is possible to design a payment mechanism (i.e. price uplifts) where demand can partially cover gas generators’ fixed costs (when spot prices cannot cover LNG costs) so as to efficiently share risks between gas generators and demand, and this will be beneficial for both since they will be in a better economical position compared to current situation. Although the case studies in this thesis are focused on the Chilean market, we believe that this is of interest to further hydrothermal systems in Latin America and Africa, which face (or will face in the near future) similar problems associated with LNG supply. Hence this research can be critical to understand the costs and benefits of various decisions associated with LNG imports and thus support a more efficient and risk-free operation and development of future electricity systems. This framework is also timely and can serve to take advantage of the present lower prices in the international LNG market.es_ES
Lenguagedc.language.isoenes_ES
Publisherdc.publisherUniversidad de Chilees_ES
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile*
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/*
Keywordsdc.subjectSistemas eléctricos hidrotérmicoses_ES
Keywordsdc.subjectProgramación estocásticaes_ES
Keywordsdc.subjectModelos matemáticoses_ES
Keywordsdc.subjectRecursos energéticoses_ES
Keywordsdc.subjectGas natural licuadoes_ES
Títulodc.titleOptimal take-or-pay Lng Supply for hydrothermal electricity systemses_ES
Document typedc.typeTesis
Catalogueruchile.catalogadorgmmes_ES
Departmentuchile.departamentoDepartamento de Ingeniería Eléctrica
Facultyuchile.facultadFacultad de Ciencias Físicas y Matemáticases_ES


Files in this item

Icon
Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Chile
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile