Control of a grinding mill circuit using fractional order controllers
Author
dc.contributor.author
Águila Camacho, Norelys
Author
dc.contributor.author
Le Roux, Johan D.
Author
dc.contributor.author
Duarte Mermoud, Manuel
Author
dc.contributor.author
Orchard Concha, Marcos
Admission date
dc.date.accessioned
2019-05-29T13:30:38Z
Available date
dc.date.available
2019-05-29T13:30:38Z
Publication date
dc.date.issued
2017
Cita de ítem
dc.identifier.citation
Journal of Process Control 53 (2017) 80–94
Identifier
dc.identifier.issn
09591524
Identifier
dc.identifier.other
10.1016/j.jprocont.2017.02.012
Identifier
dc.identifier.uri
https://repositorio.uchile.cl/handle/2250/168944
Abstract
dc.description.abstract
This paper presents the design and application of fractional single-input–single-output (SISO) controllers to a grinding mill circuit, which is a multiple-input–multiple-output (MIMO) process. Two kinds of controllers are presented: fractional order proportional-integral (FOPI) controllers, and a combination of FOPI and fractional order model reference adaptive controllers (FOMRAC). The parameters of the controller are tuned using off-line particle swarm optimization. In the presence of disturbances and process noise, the SISO fractional controllers achieve similar or better performance compared to linear model predictive control (LMPC).
Gallegos, Javier A.; Duarte Mermoud, Manuel(Institution of Engineering and Technology, 2018-06-12)
Robust backstepping control of non-linear systems with derivation orders (commensurate or non-commensurate) lying at interval (0, 2) is proposed in this study. The stability and robustness properties are proved using a ...
The modular multilevel matrix converter (M3C) is an
ac to ac power converter composed of 9 arms and is proposed
for high power applications such as motor drive and wind energy
conversion systems. Energy Control of the ...
In three-phase unbalanced systems, where the circulation of zero sequence current is necessary, four-leg converters provide a neutral connection for single-phase or other unbalanced loads typically utilized in three-phase ...