In vitro irradiation of colorectal cancer cells by pulsed radiation emitted from a hundred joules plasma focus device and its comparison with continuous irradiation
Author
dc.contributor.author
Jain, J.
Author
dc.contributor.author
Moreno, J.
Author
dc.contributor.author
Andaur, R.
Author
dc.contributor.author
Armisen, R.
Author
dc.contributor.author
Avaria, G.
Author
dc.contributor.author
Bora, B.
Author
dc.contributor.author
Davis, S.
Author
dc.contributor.author
Pavez, C.
Author
dc.contributor.author
Marcelain Cubillos, Katherine
Author
dc.contributor.author
Soto, L.
Admission date
dc.date.accessioned
2019-05-31T15:19:52Z
Available date
dc.date.available
2019-05-31T15:19:52Z
Publication date
dc.date.issued
2018
Cita de ítem
dc.identifier.citation
Journal of Physics: Conference Series, Volumen 1043, Issue 1, 2018.
Identifier
dc.identifier.issn
17426596
Identifier
dc.identifier.issn
17426588
Identifier
dc.identifier.other
10.1088/1742-6596/1043/1/012047
Identifier
dc.identifier.uri
https://repositorio.uchile.cl/handle/2250/169383
Abstract
dc.description.abstract
In the last years, pulsed reduced low dose radiation has been proposed as an alternative for treatment of recurrent cancer. Nonetheless, distinction between the effects of low dose pulsed and continuous radiation is barely known at cellular level. In order to study the effects of low dose pulsed radiation at cellular level, in vitro experiments are important to further advance the basic understanding in this area. In the present work we demonstrate the usefulness of a low-energy plasma focus device PF-400J as a potential source of low-dose pulsed radiation for in vitro cancer cell experiments. Colorectal cancer cell line, DLD-1, were irradiated by pulsed x-rays. Fifty pulses of x-rays provide ~0.12 Gy dosis, which were measured using thermoluminescence detectors (TLD-100 dosimeters). Irradiation-induced DNA damage was assessed at different time points after irradiation. A statistically significant double strand break (DSB) DNA damage was observed at 30 minutes after irradiation. A comparison of DSB induced by continuous source in the same type cancer cells and pulsed irradiation is made at 30 minutes post-irradiation. In the case of pulsed irradiation, DSB per unit dose found higher. Our findings suggest that low-energy plasma focus devices could have potential application as pulsed radiation source in the area of in vitro cancer cell experiments.
In vitro irradiation of colorectal cancer cells by pulsed radiation emitted from a hundred joules plasma focus device and its comparison with continuous irradiation