Show simple item record

Authordc.contributor.authorJain, J. 
Authordc.contributor.authorMoreno, J. 
Authordc.contributor.authorAndaur, R. 
Authordc.contributor.authorArmisen, R. 
Authordc.contributor.authorAvaria, G. 
Authordc.contributor.authorBora, B. 
Authordc.contributor.authorDavis, S. 
Authordc.contributor.authorPavez, C. 
Authordc.contributor.authorMarcelain Cubillos, Katherine 
Authordc.contributor.authorSoto, L. 
Admission datedc.date.accessioned2019-05-31T15:19:52Z
Available datedc.date.available2019-05-31T15:19:52Z
Publication datedc.date.issued2018
Cita de ítemdc.identifier.citationJournal of Physics: Conference Series, Volumen 1043, Issue 1, 2018.
Identifierdc.identifier.issn17426596
Identifierdc.identifier.issn17426588
Identifierdc.identifier.other10.1088/1742-6596/1043/1/012047
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/169383
Abstractdc.description.abstractIn the last years, pulsed reduced low dose radiation has been proposed as an alternative for treatment of recurrent cancer. Nonetheless, distinction between the effects of low dose pulsed and continuous radiation is barely known at cellular level. In order to study the effects of low dose pulsed radiation at cellular level, in vitro experiments are important to further advance the basic understanding in this area. In the present work we demonstrate the usefulness of a low-energy plasma focus device PF-400J as a potential source of low-dose pulsed radiation for in vitro cancer cell experiments. Colorectal cancer cell line, DLD-1, were irradiated by pulsed x-rays. Fifty pulses of x-rays provide ~0.12 Gy dosis, which were measured using thermoluminescence detectors (TLD-100 dosimeters). Irradiation-induced DNA damage was assessed at different time points after irradiation. A statistically significant double strand break (DSB) DNA damage was observed at 30 minutes after irradiation. A comparison of DSB induced by continuous source in the same type cancer cells and pulsed irradiation is made at 30 minutes post-irradiation. In the case of pulsed irradiation, DSB per unit dose found higher. Our findings suggest that low-energy plasma focus devices could have potential application as pulsed radiation source in the area of in vitro cancer cell experiments.
Lenguagedc.language.isoen
Publisherdc.publisherInstitute of Physics Publishing
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/
Sourcedc.sourceJournal of Physics: Conference Series
Keywordsdc.subjectPhysics and Astronomy (all)
Títulodc.titleIn vitro irradiation of colorectal cancer cells by pulsed radiation emitted from a hundred joules plasma focus device and its comparison with continuous irradiation
Document typedc.typeArtículo de revista
Catalogueruchile.catalogadorjmm
Indexationuchile.indexArtículo de publicación SCOPUS
uchile.cosechauchile.cosechaSI


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Chile
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile