Show simple item record

Authordc.contributor.authorZonno, Giacomo 
Authordc.contributor.authorAguilar, Rafael 
Authordc.contributor.authorBoroschek, Rubén 
Authordc.contributor.authorLourenço, Paulo B. 
Admission datedc.date.accessioned2019-10-11T17:30:09Z
Available datedc.date.available2019-10-11T17:30:09Z
Publication datedc.date.issued2019
Cita de ítemdc.identifier.citationEngineering Structures, Volumen 196,
Identifierdc.identifier.issn18737323
Identifierdc.identifier.issn01410296
Identifierdc.identifier.other10.1016/j.engstruct.2019.109299
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/171267
Abstractdc.description.abstract© 2019 Elsevier LtdThe analysis of the evolution of modal properties and its relationship with changes in environmental properties (i.e. ambient temperature and relative humidity) is of high importance since their effects along time can mask the influence of structural damage. While structural monitoring studies to assess the relationship between modal parameters and environmental conditions are abundantly available for modern materials constructions (i.e. concrete or steel), very few studies are reported for adobe buildings. The present paper focuses on the study of the short and long-term structural behavior of existing adobe buildings through the long-term monitoring of ambient vibration and environmental conditions. With this purpose, the paper describes in detail the case study of the San Pedro Apostol Church of Andahuaylillas located in Cusco, inside the Andean region of Peru, a 16th-century church considered as a masterpiece of South American baroque architecture. The paper star
Lenguagedc.language.isoen
Publisherdc.publisherElsevier Ltd
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/
Sourcedc.sourceEngineering Structures
Keywordsdc.subjectAdobe buildings
Keywordsdc.subjectAmbient vibration monitoring
Keywordsdc.subjectEnvironmental monitoring
Keywordsdc.subjectHistorical churches
Keywordsdc.subjectStructural and environmental correlations
Títulodc.titleAnalysis of the long and short-term effects of temperature and humidity on the structural properties of adobe buildings using continuous monitoring
Document typedc.typeArtículo de revista
Catalogueruchile.catalogadorSCOPUS
Indexationuchile.indexArtículo de publicación SCOPUS
uchile.cosechauchile.cosechaSI


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Chile
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile