Value of intraventricular dyssynchrony assessment by gated-SPECT myocardial perfusion imaging in the management of heart failure patients undergoing cardiac resynchronization therapy (VISION-CRT)
Author
dc.contributor.author
Peix, Amalia
Author
dc.contributor.author
Karthikeyan, Ganesan
Author
dc.contributor.author
Massardo Vega, Lucia Teresa del Pilar
Author
dc.contributor.author
Kalaivani, Mani
Author
dc.contributor.author
Patel, Chetan
Author
dc.contributor.author
Pabón, Luz M.
Author
dc.contributor.author
Jiménez Heffernan, Amelia
Author
dc.contributor.author
Alexanderson, Erick
Author
dc.contributor.author
Butt, Sadaf
Author
dc.contributor.author
Kumar, Alka
Author
dc.contributor.author
Marín, Víctor
Author
dc.contributor.author
Mesquita, Claudio T.
Author
dc.contributor.author
Morozova, Olga
Author
dc.contributor.author
Páez, Diana
Author
dc.contributor.author
García, Ernest V.
Admission date
dc.date.accessioned
2022-04-06T19:22:39Z
Available date
dc.date.available
2022-04-06T19:22:39Z
Publication date
dc.date.issued
2021
Cita de ítem
dc.identifier.citation
Journal of Nuclear Cardiology (2021) Volume 28, Number 1;55–64
es_ES
Identifier
dc.identifier.other
10.1007/s12350-018-01589-5
Identifier
dc.identifier.uri
https://repositorio.uchile.cl/handle/2250/184754
Abstract
dc.description.abstract
Background: Placing the left ventricular (LV) lead in a viable segment with the latest mechanical activation (vSOLA) may be associated with optimal cardiac resynchronization therapy (CRT) response. We assessed the role of gated SPECT myocardial perfusion imaging (gSPECT MPI) in predicting clinical outcomes at 6 months in patients submitted to CRT. Methods Ten centers from 8 countries enrolled 195 consecutive patients. All underwent gSPECT MPI before and 6 months after CRT. The procedure was performed as per current guidelines, the operators being unaware of gSPECT MPI results. Regional LV dyssynchrony (Phase SD) and vSOLA were automatically determined using a 17 segment model. The lead was considered on-target if placed in vSOLA. The primary outcome was improvement in >= 1 of the following: >= 1 NYHA class, left ventricular ejection fraction (LVEF) by >= 5%, reduction in end-systolic volume by >= 15%, and >= 5 points in Minnesota Living With Heart Failure Questionnaire (MLHFQ). Results Sixteen patients died before the follow-up gSPECT MPI. The primary outcome occurred in 152 out of 179 (84.9%) cases. Mean change in LV phase standard deviation (PSD) at 6 months was 10.5 degrees. Baseline dyssynchrony was not associated with the primary outcome. However, change in LV PSD from baseline was associated with the primary outcome (OR 1.04, 95% CI 1.01-1.07, P = .007). Change in LV PSD had an AUC of 0.78 (0.66-0.90) for the primary outcome. Improvement in LV PSD of 4 degrees resulted in the highest positive likelihood ratio of 7.4 for a favorable outcome. In 23% of the patients, the CRT lead was placed in the vSOLA, and in 42% in either this segment or in a segment within 10 degrees of it. On-target lead placement was not significantly associated with the primary outcome (OR 1.53, 95% CI 0.71-3.28). Conclusion LV dyssynchrony improvement by gSPECT MPI, but not on-target lead placement, predicts clinical outcomes in patients undergoing CRT.
es_ES
Lenguage
dc.language.iso
en
es_ES
Publisher
dc.publisher
Springer
es_ES
Type of license
dc.rights
Attribution-NonCommercial-NoDerivs 3.0 United States
Value of intraventricular dyssynchrony assessment by gated-SPECT myocardial perfusion imaging in the management of heart failure patients undergoing cardiac resynchronization therapy (VISION-CRT)