Abstractdc.description.abstractA bio-rack system was developed for treating Cu-contaminated freshwaters. Each pilot constructed wetland (CW, 110dm3) contained 15 perforated vertical pipes filled with a mixture of gravel (diorite; 80%) and perlite (20%) and assembled as a rack. The whole experimental device consisted of 12 CW planted either with Phragmites australis, Phalaris arundinacea or Juncus articulatus, and unplanted as control (in triplicates). All plants were sampled at a Cu-contaminated site. The CWs were filled with a mix of freshwater (30%) from the Jalle d'Eysines River (Bordeaux, France) and tap water (70%). Water was spiked with Cu (2.5μM, 158.5μgL-1). Three CW batches were carried out, i.e. in early spring (March, S#1), beginning of the growing season (May, S#2), and peak growing season (June, S#3). The S#3 water was initially acidified to pH 6. For all batches, water was recirculated in the CW during 14 days. Physico-chemical parameters (pH, electrical conductivity, redox potential, BOD5 and Cu2+ con
Lenguagedc.language.isoen
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/
Sourcedc.sourceEcological Engineering
Keywordsdc.subjectBiofilm
Keywordsdc.subjectConstructed wetland
Keywordsdc.subjectDecontamination
Keywordsdc.subjectMacrophyte
Keywordsdc.subjectPhytoremediation
Títulodc.titleCopper removal from water using a bio-rack system either unplanted or planted with Phragmites australis, Juncus articulatus and Phalaris arundinacea
Document typedc.typeArtículo de revista
Catalogueruchile.catalogadorSCOPUS
Indexationuchile.indexArtículo de publicación SCOPUS
uchile.cosechauchile.cosechaSI


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Chile
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile