Show simple item record

Authordc.contributor.authorPipelzadeh, Yousef 
Authordc.contributor.authorMoreno Vieyra, Rodrigo 
Authordc.contributor.authorChaudhuri, Balarko 
Authordc.contributor.authorStrbac, Goran 
Authordc.contributor.authorGreen, Tim C. 
Admission datedc.date.accessioned2019-05-29T13:10:36Z
Available datedc.date.available2019-05-29T13:10:36Z
Publication datedc.date.issued2017
Cita de ítemdc.identifier.citationIEEE Transactions on Power Systems, Volumen 32, Issue 2, 2017, Pages 1638-1650
Identifierdc.identifier.issn08858950
Identifierdc.identifier.other10.1109/TPWRS.2016.2598815
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/168837
Abstractdc.description.abstractIn this paper, the efficacy and value of using correc-tive control supported by transient assistive measures (TAM) isquantified in terms of the cost savings due to less constrained oper-ation of the system. The example TAM is a rapid modulation of thepower order of the high-voltage direct current (HVDC) links in thesystem so as to improve transient stability during corrective con-trol. A sequential approach is used for the offline value assessment:a security constrained economic dispatch (SCED) module (masterproblem) determines the optimal generation dispatch, HVDC set-tings, and the corrective control actions to be used post-fault (gen-eration and demand curtailed) so as to minimize the operationalcosts while ensuring static security. The transient stability mod-ule (slave problem) assesses the dynamic stability for the operatingcondition set by the SCED and, if needed, applies appropriate TAMto maintain the system transiently stable. If this is not possible, themaster module uses a tighter set of security constraints to updatethe dispatch and other settings until the system can be stabilized. Acase-study on the Great Britain system is used to demonstrate thatcorrective control actions supported by TAM facilitate significantlyhigher pre-fault power transfers whilst maintaining N-2 security.
Lenguagedc.language.isoen
Publisherdc.publisherIEEE
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/
Sourcedc.sourceIEEE Transactions on Power Systems
Keywordsdc.subjectCorrective control
Keywordsdc.subjectEconomic dispatch
Keywordsdc.subjectFACTS
Keywordsdc.subjectHVDC transmission
Keywordsdc.subjectPower system economics
Keywordsdc.subjectSystem security
Keywordsdc.subjectTransient stability
Títulodc.titleCorrective Control with Transient Assistive Measures: Value Assessment for Great Britain Transmission System
Document typedc.typeArtículo de revista
Catalogueruchile.catalogadorlaj
Indexationuchile.indexArtículo de publicación SCOPUS
uchile.cosechauchile.cosechaSI


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Chile
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile