Show simple item record

Authordc.contributor.authorGaray, Rose Marie 
Authordc.contributor.authorHerrera, Ricardo 
Authordc.contributor.authorMejías, Claudio 
Admission datedc.date.accessioned2019-10-30T15:40:22Z
Available datedc.date.available2019-10-30T15:40:22Z
Publication datedc.date.issued2019
Cita de ítemdc.identifier.citationRevista de la Construccion, Volumen 18, Issue 1, 2019, Pages 68-86
Identifierdc.identifier.issn0718915X
Identifierdc.identifier.issn07177925
Identifierdc.identifier.other10.7764/RDLC.18.1.68
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/172600
Abstractdc.description.abstractAs part of the Fondef D09I1058 project, an emergency housing solution was developed and five prototypes constructed. The prototypes solved mechanical, thermal, water tightness and airtightness problems common to emergency housing, achieving a minimum durability of five years. Emergency housing does not fall under the jurisdiction of permanent housing codes, hence, there are no requirements that these houses must meet. A first step towards establishing minimum requirements is the evaluation of the current emergency housing solutions. This paper presents the structural evaluation of these prototypes. The prototypes were fabricated with "structural insulated panels" (SIPs), which provide structural strength and thermal insulation, for four thermal zones of the country. All the prototypes presented adequate structural performance. Out of all the locations considered, only two houses presented minor strength problems in the roof structure, but almost satisfied the requirements indicated by the codes for permanent social housing. In the case of the floor diaphragms, only one prototype fell short 97.5% of the required strength, which was considered acceptable this emergency housing. For the walls, laboratory tests, performed applying lateral and out-of-plane loads on the panels that compose the prototypes, established that they could withstand the design earthquake loads and wind loads.
Lenguagedc.language.isoen
Publisherdc.publisherPontificia Universidad Catolica de Chile, Escuela de Construccion Civil
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/
Sourcedc.sourceRevista de la Construccion
Keywordsdc.subjectEmergency house
Keywordsdc.subjectHabitability
Keywordsdc.subjectShelter
Keywordsdc.subjectSIP panel
Keywordsdc.subjectStructural timber frame
Keywordsdc.subjectTechnical and normative standards for emergency houses
Títulodc.titleProject shelter, Part 2: Structural verification
Document typedc.typeArtículo de revista
dcterms.accessRightsdcterms.accessRightsAcceso Abierto
Catalogueruchile.catalogadorSCOPUS
Indexationuchile.indexArtículo de publicación SCOPUS
uchile.cosechauchile.cosechaSI


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Chile
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile