Show simple item record

Authordc.contributor.authorVieira, Camila M. S. 
Authordc.contributor.authorMafra, Gabriela 
Authordc.contributor.authorBrognoli, Rafael 
Authordc.contributor.authorRichter Duk, Pablo 
Authordc.contributor.authorRosero Moreano, Milton 
Authordc.contributor.authorCarasek, Eduardo 
Admission datedc.date.accessioned2020-06-02T19:37:44Z
Available datedc.date.available2020-06-02T19:37:44Z
Publication datedc.date.issued2020
Cita de ítemdc.identifier.citationTalanta 208 (2020) 120459es_ES
Identifierdc.identifier.other10.1016/j.talanta.2019.120459
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/175148
Abstractdc.description.abstractIn this study, a high throughput approach to rotating-disk sorptive extraction (RDSE) using laminar cork as extraction phase is demonstrated for the first time in the determination of 20 multiclass organic micro-pollutants including pesticides, PAHs and UV filters compounds from aqueous samples with gas chromatography mass spectrometry (GC-MS). The influencing parameters (desorption solvent, volume and time, extraction time and sample pH and ionic strength) were carefully optimized using multivariate designs. The optimal conditions were 10 min for extraction using 35 mL of water samples and a liquid desorption using 1 mL of MeOH:AcOEt (50:50% v/v) for 20 min. A low-cost apparatus that allows six extractions simultaneously, providing a high throughput of 5 min per sample turnaround times, considering the sample preparation step was used for the first time in this modified RDSE methodology. Satisfactory analytical performance was achieved with limits of detection (LOD) between 0.08 and 1.5 mu g L-1 and limits of quantification (LOQ) between 0.3 and 4.8 mu g L-1. The relative recoveries for the analytes were determined using river and lake water samples spiked at different concentrations and ranging from 80% to 119% for all analytes, with relative standard deviations (RSD) lower than 20%. The extraction efficiency obtained for the proposed configuration with laminar cork was significantly superior to powdered cork, demonstrating an interesting new configuration for new applications.es_ES
Patrocinadordc.description.sponsorshipNational Council for Scientific and Technological Development (CNPq). CAPES.es_ES
Lenguagedc.language.isoenes_ES
Publisherdc.publisherElsevieres_ES
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile*
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/*
Sourcedc.sourceTalantaes_ES
Keywordsdc.subjectRotating-disk sorptive extractiones_ES
Keywordsdc.subjectCorkes_ES
Keywordsdc.subjectOrganic micro-pollutantses_ES
Keywordsdc.subjectMieroextractiones_ES
Keywordsdc.subjectEnvironmental water sampleses_ES
Títulodc.titleA high throughput approach to rotating-disk sorptive extraction (RDSE) using laminar cork for the simultaneous determination of multiclass organic micro-pollutants in aqueous sample by GC-MSes_ES
Document typedc.typeArtículo de revistaes_ES
dcterms.accessRightsdcterms.accessRightsAcceso Abierto
Catalogueruchile.catalogadorrvhes_ES
Indexationuchile.indexArtículo de publicación ISI
Indexationuchile.indexArtículo de publicación SCOPUS


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Chile
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile