Show simple item record

Professor Advisordc.contributor.advisorMcphee Torres, James
Authordc.contributor.authorGonzález Gallardo, Rodrigo Antonio
Associate professordc.contributor.otherDaniele, Linda
Associate professordc.contributor.otherHayashi, Masaki
Admission datedc.date.accessioned2025-03-21T16:04:43Z
Available datedc.date.available2025-03-21T16:04:43Z
Publication datedc.date.issued2024
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/203748
Abstractdc.description.abstractLa estimación precisa de los flujos superficiales y subterráneos permiten una gestión de recursos hídricos confiable, más aún considerando que Chile está atravesando un período complejo de mega sequía. Estudios recientes han identificado un flujo subterráneo proveniente de la cordillera en la zona central de Chile. En concreto, algunas mediciones en los acuíferos aluviales muestran que no son consistentes con la variación estacional de precipitación y acumulación de nieve. Para medir la cantidad de recarga subterránea proveniente de la cordillera de Los Andes, se desarrolló un modelo cuasi 2D para estudiar el modelo presentado por Taucare, Daniele, et al. (2020), el cual presenta diferentes mecanismos de infiltración, acumulación de nieve y circulación del agua. El modelo implementado es ParFlow, el cual es un modelo de aguas subterráneas que permite acoplar un modelo superficial y EcoSLIM, el cual es un modelo de seguimiento de partículas que permite estudiar las distribuciones de los tiempos de residencia. El estudio fue distribuido en 3 etapas: Etapa 1 implementa ParFlow acoplado con Community Land Model, buscando desarrollar condiciones de borde, estudiar la distribución espacial de la infiltración, evapotranspiración y el equivalente agua nieve durante un periodo de 100 años (repitiendo periodo 1960 a 1696 10 veces); La Etapa 2 implementa ParFlow, el cual recibe la infiltración y las condiciones de borde de la Etapa 1 e implementa 6 escenarios (4 donde varía la conductividad hidráulica y se mantiene constante la infiltración, 1 donde varía la infiltración y se mantiene la conductividad hidráulica y 1 utilizado como caso base), modelando en estado estable donde se busca un flujo de aguas subterráneas de salida, o recarga del bloque de montaña, para cada escenario; Etapa 3 implementa EcoSLIM para estimar las distribuciones de tiempos de residencia de cada escenario evaluado en la etapa 2 durante 400 años. Los resultados principales son: Todos los escenarios tienen tiempos de residencia entre 14,3 [año] a 107,5 [año], cayendo dentro del rango notificado por trabajos de terreno; El flujo de salida (o recarga del bloque de montaña) de todos los escenarios fluctúa entre 50,1 [mm/año] a 146,6 [mm/año], donde el escenario base (82,91 [mm/año]) y el escenario de variación de infiltración (70,4 [mm/año]) son muy cercanos a los valores reportados por otros estudios de recarga de la cuenca del Río Aconcagua.es_ES
Abstractdc.description.abstractAccurate estimation of surface and underground fluxes allows reliable management of water resources, even more so considering that Chile is coming through a complex scenario with the mega drought. Recent studies have identified a subsurface flux through the mountains in the central zone of Chile. In specific, the valley aquifers near the Andes show well measurements that are not consistent with seasonal shifts in precipitation and snow accumulation. To quantify the amount of subsurface recharge coming from the Andes Mountain range, a quasi-2D numerical model is developed to validate the conceptual model presented by Taucare, Daniele, et al. (2020), which presents different mechanisms of infiltration, snow accumulation, and water circulation. The numerical model was implemented is ParFlow, which is a groundwater model that allows coupling with a surface model, and EcoSLIM, a particle tracking model for studying the residence time distribution of groundwater. The study was distributed in three stages: Stage 1 implements ParFlow coupled with Community Land Model to develop boundary conditions, study the spatial distribution of infiltration, evapotranspiration, and snow water equivalent and finally obtain an amount of infiltration for all study area during a period of 100 years (period 1960 to 1969 is repeated 10 times); Stage 2 implements ParFlow, which receives the infiltration and boundary conditions from the previous stage and implement 6 scenarios (4 where the hydraulic conductivity varies but maintain infiltration, 1 where the infiltration is varied but maintain hydraulic conductivity setup, and 1 were considered as base scenario), modeling in steady state looking for a total amount of subsurface outflow or mountain block recharge for each scenario; and Stage 3 implement EcoSLIM for estimate the residence time distribution of water for each scenario with results of Stage 2 during 400 years. The main results are: All scenarios have residence times between 14,3 [𝑦�] and 107,5[𝑦�], which falls within a range of 10’s to 100’s years of residence time given by fieldwork; The subsurface outflow (or mountain block recharge) of all scenarios varies from 50,1 [𝑚�𝑚�/ 𝑦�] to 146,6[𝑚�𝑚�/𝑦�], where base scenario (82,91 [𝑚�𝑚�/𝑦�]) and infiltration var scenario (70,4 [𝑚�𝑚�/𝑦�]) are closely align with to investigations of groundwater recharge of Aconcagua River basin aquifers.es_ES
Patrocinadordc.description.sponsorshipEste trabajo fue financiado por la Agencia Nacional de Investigación y Desarrollo. ATE220029es_ES
Lenguagedc.language.isoenes_ES
Publisherdc.publisherUniversidad de Chilees_ES
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States*
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
Títulodc.titleRecharge modelling in a high mountain hydrological systemes_ES
Document typedc.typeTesises_ES
dc.description.versiondc.description.versionVersión original del autores_ES
dcterms.accessRightsdcterms.accessRightsAcceso abiertoes_ES
Catalogueruchile.catalogadorchbes_ES
Departmentuchile.departamentoDepartamento de Ingeniería Civiles_ES
Facultyuchile.facultadFacultad de Ciencias Físicas y Matemáticases_ES
uchile.carrerauchile.carreraIngeniería Civiles_ES
uchile.gradoacademicouchile.gradoacademicoLicenciadoes_ES
uchile.notadetesisuchile.notadetesisMemoria para optar al título de Ingeniero Civiles_ES


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States