Show simple item record

Authordc.contributor.authorCarrera, M. E. 
Authordc.contributor.authorRodríguez, V. es_CL
Authordc.contributor.authorToral Ponce, María es_CL
Authordc.contributor.authorRichter Duk, Pablo es_CL
Admission datedc.date.accessioned2010-11-17T14:02:25Z
Available datedc.date.available2010-11-17T14:02:25Z
Publication datedc.date.issued1993
Cita de ítemdc.identifier.citationAnalytical Letters 26 (12): 2575-2585en_US
Identifierdc.identifier.issn0003-2719
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/121127
Abstractdc.description.abstractThis paper describes a method for the quantitative determination of aluminium in haemodialysis concentrates, based on the adsorption on a static mercury drop electrode of the Al-1,2 dihydroxyantraquinone-3-sulphonic acid complex. The signal was notably increased in presence of calcium. The electrolysis was carried out at-0.900 V. After 60sec the aluminium contents were measured by differential pulse voltammetry. In these conditions aluminium can be determined in the range 0.65 - 30ng/ml with a detection limit (3Ó) of 0.20 ng/ml. The relative standard deviation was in all instances less than 2.1%.en_US
Lenguagedc.language.isoenen_US
Publisherdc.publisherMarcel Dekker, Incen_US
Keywordsdc.subjectAluminiumen_US
Títulodc.titleVoltammetric determination of aluminium in haemodialysis concentrates using the adsorption of the Al (III)-1,2-dihydroxyantraquinone-3-sulphonic acid complex in presence of calcium.en_US
Document typedc.typeArtículo de revista


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record