Admission datedc.date.accessioned2015-10-26T20:27:24Z
Available datedc.date.available2015-10-26T20:27:24Z
Publication datedc.date.issued2015
Cita de ítemdc.identifier.citationRadiation Protection Dosimetry (2015), pp. 1–4en_US
Identifierdc.identifier.otherdoi:10.1093/rpd/ncv035
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/134658
General notedc.descriptionArtículo de publicación ISIen_US
Abstractdc.description.abstractThe aim of this work was to analyse the radiation dose for patients and staff between X-ray systems, a new biplane with flat-panel detectors (FDs) and a conventional system equipped with image intensifier (II). Entrance surface air kerma (ESAK) and scatter doses were measured on polymethyl methacrylate (PMMA) phantoms of different thicknesses (from 4 to 16 cm). The ESAK values for the different acquisition modes and PMMA thicknesses were higher for the II in comparison with FDs. For the II, the scatter dose rates ranged from 0.67 to 12.2 mSv h(-1) at the eye position of the cardiologist during fluoroscopy and cine modes. At the lower extremities, these values were 1.11 and 24.24 mSv h(-1). In the case of the FDs, these values ranged from 0.24 to 0.67 mSv h(-1) for eye lens and from 0.73 to 2.01 mSv h(-1) for the position of cardiologist's ankle. The newly installed X-ray system showed an average reduction factor of up to 9.7 times for ESAK values. For the staff with an average reduction factor of 15.9 times at the eye position during fluoroscopy and cine modes, no protective tools are used. At the lower extremities, this value was 7.6 times.en_US
Patrocinadordc.description.sponsorshipTarapaca University 7710-14en_US
Lenguagedc.language.isoenen_US
Publisherdc.publisherOxford Univ Pressen_US
Type of licensedc.rightsAtribución-NoComercial-SinDerivadas 3.0 Chile*
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/*
Keywordsdc.subjectCardiac proceduresen_US
Keywordsdc.subjectImage qualityen_US
Keywordsdc.subjectPatienten_US
Títulodc.titleComparison of two Angiographic Systems Inpaediatric Interventional Cardiologyen_US