A molecularly imprinted polymer as the sorptive phase immobilized in a rotating disk extraction device for the determination of diclofenac and mefenamic acid in wastewater
Author
dc.contributor.author
Manzo, Valentina
Author
dc.contributor.author
Ulisse Ulisse, Karla
Author
dc.contributor.author
Rodríguez, Inés
Author
dc.contributor.author
Pereira, Eduardo
Author
dc.contributor.author
Richter Duk, Pablo
Admission date
dc.date.accessioned
2015-11-27T14:19:25Z
Available date
dc.date.available
2015-11-27T14:19:25Z
Publication date
dc.date.issued
2015
Cita de ítem
dc.identifier.citation
Analytica Chimica Acta 889 (2015) 130-137
en_US
Identifier
dc.identifier.other
DOI: 10.1016/j.aca.2015.07.038
Identifier
dc.identifier.uri
https://repositorio.uchile.cl/handle/2250/135290
General note
dc.description
Artículo de publicación ISI
en_US
Abstract
dc.description.abstract
The microextraction of diclofenac and mefenamic acid from water samples was performed by using rotating disk sorptive extraction (RDSE) with molecularly imprinted polymer (MIP) as the sorptive phase. The MIP was synthesized from the monomer 1-vinylimidazol (VI) together with the cross-linker divinylbenzene (DVB) using diphenylamine as the template molecule. Scanning electron microscopy (SEM) analyses of the MIP revealed clusters of spherical particles having a narrow size distribution, with diameters of approximately 1 mm.
The optimized extraction conditions involved a disk rotation velocity of 3000 rpm, an extraction time of 120 min, a sample volume of 50 mL, and a sample pH of 2 as well as 25 mg of MIP immobilized in the disk. Desorption of the extracted analytes was performed with 5 mL of methanol for 10 min. Analysis by gas chromatography-mass spectrometry (GC-MS) was carried out after derivatization of the analytes with N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide (MTBSTFA).
Nonmolecularly imprinted polymer(NIP) was also synthesized for comparison. It was observed that under the same conditions, MIP extracted significantly more NSAIDs containing diphenylamine (or part of this molecule) in their structure than NIP. Higher significant differences between MIP and NIP were observed for diclofenac, mefenamic acid and paracetamol, clearly indicating the effect of the template on the extraction.
Recoveries of the method were between 100 and 112%, with relative standard deviations of 5-6%. The limits of detection were between 60 and 223 ng L-1. Water samples from a wastewater treatment plant (WWTP) of Santiago de Chile, were found to contain concentrations of these acidic drugs between 1.6 and 4.3 mg L-1 and between 1.4 and 3.3 mg L-1 in the influent and effluent, respectively.
A molecularly imprinted polymer as the sorptive phase immobilized in a rotating disk extraction device for the determination of diclofenac and mefenamic acid in wastewater