Show simple item record

Authordc.contributor.authorHevia, J. 
Authordc.contributor.authorFresno Rivas, María Consuelo 
Authordc.contributor.authorMartín Casielles, Javier 
Authordc.contributor.authorMoncada, G. 
Authordc.contributor.authorLetelier, C. 
Authordc.contributor.authorOliveira, Osmir Batista 
Authordc.contributor.authorFernández Godoy, Eduardo 
Admission datedc.date.accessioned2016-11-07T20:22:21Z
Available datedc.date.available2016-11-07T20:22:21Z
Publication datedc.date.issued2013
Cita de ítemdc.identifier.citationRev. Clin. Periodoncia Implantol. Rehabil. Oral Vol. 6(3); 114-117, 2013.es_ES
Identifierdc.identifier.issn0719-0107
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/141149
Abstractdc.description.abstractterceros molares sanos, con indicación de exodoncia, de donantes sanos de edades entre 15 y 30 años fueron obtenidos mediante consentimiento informado. Luego de limpiarlos, desinfectarlos, incluirlos en resina epóxica y cortarlos se obtuvieron 17 muestras de dentina, correspondiente a un disco de resina con un corte coronal de diente que presenta dentina expuesta en ambas caras de éste. Tres equipos para medir la conductancia hidráulica de la dentina fueron armados siguiendo la descripción del modelo de Pashley. Las muestras fueron instaladas en una cámara de difusión, conectada mediante tubos de silicona a una pipeta graduada y una columna de agua de 20cm. Mediante el desplazamiento de una burbuja de agua al interior de la pipeta, se midió la conductancia hidráulica de cada muestra, 3 veces los días 14, 21, 28 y 35 postextracción. Los datos fueron tabulados y analizados estadísticamente. No existe diferencia en la tasa de flujo de una muestra medida en los tres equipos (p=0.5937). No existe diferencia en las mediciones de la conductancia hidráulica de 13 muestras de dentina humana medida en los días 14, 21, 28 y 35 postextracción (p=0.0704). Es posible montar un modelo experimental para estudiar la conductancia hidráulica de la dentina ex vivo, basado en el modelo de Pashley y col. El modelo pareciera ser confiable, pero es necesaria más investigación para poder validar su confiabilidad.es_ES
Abstractdc.description.abstractThe main objective of this work was to mount and test an experimental model to measure the hydraulic conductance of ex vivo dentin. Seventeen healthy third molars, with indication of extraction of healthy donors aged between 15 and 30 years were obtained by informed consent. After cleaning them, disinfecting them, including them in resin epoxy and cutting them, there were 17 samples of dentin, corresponding to a disk of resin with a coronal section of tooth showing the dentin exposed on both sides of it. Three machines to measure the hydraulic conductance of the dentin were assembled according to the description of the model of Pashley. Samples were installed in a Chamber of diffusion, connected by using silicone tubes to a graduated transfer pipette and a 20cm water column. Through the displacement of a bubble of water in the inside of the pipette, the hydraulic conductance of each sample was measured 3 times on the 14th, 21st, 28th and 35th day post extraction. The data were tabulated and analyzed statistically. There is no SS difference in the rate of flow of a measured sample in the three machines (p=0.5937). There is no SS difference in measurements of the hydraulic conductance of 13 samples of human dentin measured in days 14, 21, 28 and 35 postextraction (p=0.0704). It is possible to mount an experimental model to study the hydraulic conductance of dentin ex vivo, based on the model of Pashley. The model seems to be reliable, but more research is needed in order to validate its reliability.es_ES
Lenguagedc.language.isoeses_ES
Publisherdc.publisherSociedad de Periodoncia de Chilees_ES
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile*
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/*
Sourcedc.sourceRevista Clínica de Periodoncia, Implantología y Rehabilitación Orales_ES
Keywordsdc.subjectDentinaes_ES
Keywordsdc.subjectConductanciaes_ES
Keywordsdc.subjectDifusiónes_ES
Keywordsdc.subjectDentines_ES
Keywordsdc.subjectDiffusiones_ES
Títulodc.titleModelo de conductancia hidráulica de la dentina humana ex vivoes_ES
Title in another languagedc.title.alternativeHydraulic conductance model of ex vivo human dentines_ES
Document typedc.typeArtículo de revista
Catalogueruchile.catalogadorlajes_ES
Indexationuchile.indexArtículo de publicación SCIELOes_ES