Show simple item record

Authordc.contributor.authorAguirre, Daniel 
Authordc.contributor.authorPincetti, Christian 
Authordc.contributor.authorPérez, Luis 
Authordc.contributor.authorDeck, Carlos 
Authordc.contributor.authorAlfaro, Mario 
Authordc.contributor.authorVergara, María Jesús 
Authordc.contributor.authorMaluenda Razeto, Gabriel 
Admission datedc.date.accessioned2018-07-26T21:01:45Z
Available datedc.date.available2018-07-26T21:01:45Z
Publication datedc.date.issued2018
Cita de ítemdc.identifier.citationCatherterization and Cardiovascular Interventions Volumen: 91 Número: 2 Páginas: 356-361es_ES
Identifierdc.identifier.other10.1002/ccd.27246
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/150363
Abstractdc.description.abstractObjectiveThis registry aimed to describe the safety and feasibility of a single trans-septal (TS) access technique for left intracardiac echocardiography (ICE) guidance of left-atrial appendage (LAA) closure procedure. BackgroundLAA closure is currently accepted as an alternative to oral anticoagulation (OAC) in patients with non-valvular atrial fibrillation (NVAF) who are at high-risk for bleeding. Currently, LAA closure procedure is typically performed under trans-esophageal echocardiogram (TEE) guidance. Although, ICE has the advantage of not requiring profound sedation/anesthesia, ICE-LAA imaging quality is often limited from the right atrium requiring double TS access. MethodsTwenty-two patients with NVAF underwent LAA closure using the Amplatzer Amulet device (St Jude Medical) under ICE guidance from the left atrium. The ICE AcuNav catheter (Biosense Webster) and the Amulet delivery sheath were advanced into the LA through single TS puncture technique. ResultsThe population was predominately male (59.1%) with a mean age of 749.3 years, at high-risk for stroke (mean CHADS2 score of 3.8 +/- 1.1) and bleeding (mean HAS BLED score of 3.5 +/- 1.3). The Amplatzer Amulet(TM) device was successfully implanted in all patients. No procedural related complications including device embolization were noted. No major cardiovascular events occurred and all patients were discharged alive. At 30-day follow-up all patients remained alive, free of ischemic stroke and with no residual leak or device thrombus on TEE. ConclusionsThis initial experience suggests that LAA occlusion with the Amplatzer Amulet device using ICE guidance from the left atrium via a single trans-septal technique is feasible and safe.es_ES
Lenguagedc.language.isoenes_ES
Publisherdc.publisherWileyes_ES
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile*
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/*
Sourcedc.sourceCatherterization and Cardiovascular Interventionses_ES
Keywordsdc.subjectIntracardiac echocardiogrames_ES
Keywordsdc.subjectLeft-atrial appendage closurees_ES
Keywordsdc.subjectTrans-septales_ES
Títulodc.titleSingle trans-septal access technique for left atrial intracardiac echocardiography to guide left atrial appendage closurees_ES
Document typedc.typeArtículo de revista
Catalogueruchile.catalogadorrgfes_ES
Indexationuchile.indexArtículo de publicación ISIes_ES


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Chile
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile