Polarographic behaviour and determination of nitrofurantoin, chloramphenicol and related compounds
Author
dc.contributor.author
Morales, Alfonso
Author
dc.contributor.author
Toral Ponce, María
Author
dc.contributor.author
Richter Duk, Pablo
Admission date
dc.date.accessioned
2018-12-20T15:05:08Z
Available date
dc.date.available
2018-12-20T15:05:08Z
Publication date
dc.date.issued
1984
Cita de ítem
dc.identifier.citation
The Analyst, Volumen 109, Issue 5, 1984, Pages 633-636
Identifier
dc.identifier.issn
00032654
Identifier
dc.identifier.other
10.1039/AN9840900633
Identifier
dc.identifier.uri
https://repositorio.uchile.cl/handle/2250/157680
Abstract
dc.description.abstract
The polarographic behaviour of nitrofurantoin and chloramphenicol have been studied in pyridine - formic acid buffer and tetramethylammonium chloride solution at pH 4.3. The E<inf>1/2</inf> versus pH and iym versus pH relationships show that the E<inf>1/2</inf> values are pH dependent and that the current is independent of pH except when acid - base equilibria affect it. The difference in E<inf>1/2</inf> values (230 mV) makes simultaneous determination possible. Simultaneous determinations of both drugs were performed in a concentration range suitable for application to pharmaceutical formulations and body fluids. Other nitro derivatives can also be determined without interference. The standard additions technique provided results as satisfactory as the use of a calibration graph. The proposed method has the advantage over previously used electrochemical methods of not requiring prior separations.