Authordc.contributor.authorLeiva Guzmán, Manuel 
Authordc.contributor.authorGonzales, Benjamin 
Authordc.contributor.authorVargas, Daniela 
Authordc.contributor.authorToro, Richard 
Authordc.contributor.authorMorales Segura, Raúl 
Admission datedc.date.accessioned2018-12-20T15:10:53Z
Available datedc.date.available2018-12-20T15:10:53Z
Publication datedc.date.issued2013
Cita de ítemdc.identifier.citationMicrochemical Journal, Volumen 110,
Identifierdc.identifier.issn0026265X
Identifierdc.identifier.other10.1016/j.microc.2013.05.004
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/158286
Abstractdc.description.abstractAmmonia, one of the ambient gasses that require environmental monitoring, is typically measured using a passive sampling method. The present work presents an evaluation of the uncertainty according to the Guide to the Expression of Uncertainty in Measurement for the measurement of the atmospheric ammonia concentration as determined by an Ogawa passive sampler, using a colorimetric method. The analytical results report the uncertainty only as a standard deviation of repeated measurements, but not all sources of uncertainty are considered. In this work, the major sources of uncertainty in the measurements are identified as contributions to the linear least-square regression lines, repeatability and recovery. The result, including the expanded uncertainty (k=2) at a level of confidence of 95%, is 39.2%. The aforementioned results indicate that the Ogawa sampler can be successfully deployed to estimate the atmospheric NH3 and could find wide application in environmental monitoring. However
Lenguagedc.language.isoen
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/
Sourcedc.sourceMicrochemical Journal
Keywordsdc.subjectAtmospheric ammonia concentration
Keywordsdc.subjectGUM
Keywordsdc.subjectOgawa passive sampler
Keywordsdc.subjectUncertainty estimation
Títulodc.titleEstimating the uncertainty in the atmospheric ammonia concentration in an urban area by Ogawa passive samplers
Document typedc.typeArtículo de revista
Catalogueruchile.catalogadorSCOPUS
Indexationuchile.indexArtículo de publicación SCOPUS