Show simple item record

Authordc.contributor.authorLópez Cisternas, Juan 
Authordc.contributor.authorCastillo Díaz, Jessica 
Authordc.contributor.authorTraipe Castro, Leonidas 
Authordc.contributor.authorLópez Solís, Remigio 
Admission datedc.date.accessioned2019-03-11T12:54:13Z
Available datedc.date.available2019-03-11T12:54:13Z
Publication datedc.date.issued2007
Cita de ítemdc.identifier.citationCornea, Volumen 26, Issue 8, 2018, Pages 970-976
Identifierdc.identifier.issn02773740
Identifierdc.identifier.other10.1097/ICO.0b013e318093de64
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/164370
Abstractdc.description.abstractPURPOSE: To develop a method to quantify tear protein concentration with the sensitivity to measure this variable in the restricted volumes of single human tear samples. METHODS: Aliquots of tear fluid from healthy subjects and a solution of standard bovine serum albumin (BSA) were spotted on cellulose membranes. Membranes were fixed, stained for protein with Coomassie blue, and washed until they displayed clear backgrounds. Stained spots were excised and eluted in a defined volume of methanol-ammonia, and the absorbance was determined spectrophotometrically at 610 nm. Membranes were calibrated by calculating their apparent thickness from the areas of stained spots and the corresponding aliquot volumes of either tear fluid or BSA solution. RESULTS: In our dye-binding assay, absorbance (0-1.00 OD) was found to have a linear relation with tear fluid volume (1-7 μL). In a study involving samples from 33 healthy subjects, aliquots (3 μL) of tear fluid were found to yield absorbances in the
Lenguagedc.language.isoen
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/
Sourcedc.sourceCornea
Keywordsdc.subjectCoomassie blue
Keywordsdc.subjectElectrophoresis
Keywordsdc.subjectHuman
Keywordsdc.subjectProtein dye-binding assay
Keywordsdc.subjectTear
Títulodc.titleA protein dye-binding assay on cellulose membranes for tear protein quantification: Use of conventional Schirmer strips
Document typedc.typeArtículo de revista
Catalogueruchile.catalogadorSCOPUS
Indexationuchile.indexArtículo de publicación SCOPUS
uchile.cosechauchile.cosechaSI


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Chile
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile