Show simple item record
Author | dc.contributor.author | Brunser, Alejandro M. | |
Author | dc.contributor.author | Lavados Germain, Pablo Manuel | |
Author | dc.contributor.author | Cárcamo, Daniel A. | |
Author | dc.contributor.author | Hoppe, Arnold | |
Author | dc.contributor.author | Olavarría, Verónica V. | |
Author | dc.contributor.author | López, Javiera | |
Author | dc.contributor.author | Muñoz, Paula | |
Author | dc.contributor.author | Palacios Rivas, Rodrigo | |
Admission date | dc.date.accessioned | 2019-03-18T11:52:57Z | |
Available date | dc.date.available | 2019-03-18T11:52:57Z | |
Publication date | dc.date.issued | 2015 | |
Cita de ítem | dc.identifier.citation | Journal of Medical Ultrasound, Volumen 23, Issue 1, 2018, Pages 29-33 | |
Identifier | dc.identifier.issn | 09296441 | |
Identifier | dc.identifier.other | 10.1016/j.jmu.2014.07.002 | |
Identifier | dc.identifier.uri | https://repositorio.uchile.cl/handle/2250/166555 | |
Abstract | dc.description.abstract | © 2014.Background: The diagnosis of brain death (BD) is complex. For this reason, we aimed to evaluate the accuracy of power mode transcranial Doppler (PMD-TCD) in diagnosing BD. Patients and methods: Patients admitted to an intensive care unit between December 2003 and January 2012 were included in this study if they were in a structural coma, had no craniectomy, and were evaluated blind by a neurologist using PMD-TCD. The diagnosis of BD was based on an evaluation that took into consideration the absence of sedative drugs, a median blood pressure >60mmHg, a body temperature >35°C, and the absence of brainstem reflexes. A neurosonologist followed a protocol using PMD-TCD that considered the examination as positive for brain circulatory arrest given the presence of reverberating, small systolic peaks or the disappearance of a previous signal present in both middle cerebral arteries and intracranial vertebral arteries. Results: A total of 74 patients were evaluated. In 61 (82.4%) patien | |
Lenguage | dc.language.iso | en | |
Publisher | dc.publisher | Elsevier (Singapore) Pte Ltd | |
Type of license | dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Chile | |
Link to License | dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/cl/ | |
Source | dc.source | Journal of Medical Ultrasound | |
Keywords | dc.subject | Brain death | |
Keywords | dc.subject | Doppler ultrasound | |
Keywords | dc.subject | Power mode transcranial Doppler ultrasound | |
Keywords | dc.subject | Ultrasound diagnosis | |
Keywords | dc.subject | Ultrasound Doppler sonography | |
Título | dc.title | Accuracy of power mode transcranial Doppler in the diagnosis of brain death | |
Document type | dc.type | Artículo de revista | |
dcterms.accessRights | dcterms.accessRights | Acceso Abierto | |
Cataloguer | uchile.catalogador | SCOPUS | |
Indexation | uchile.index | Artículo de publicación SCOPUS | |
uchile.cosecha | uchile.cosecha | SI | |
Files in this item
- Name:
- j.jmu.2014.07.002.pdf
- Size:
- 12.90Kb
- Format:
- PDF
This item appears in the following Collection(s)
Show simple item record
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile