Show simple item record

Authordc.contributor.authorToro A., Richard 
Authordc.contributor.authorCampos, Claudia 
Authordc.contributor.authorMolina, Carolina 
Authordc.contributor.authorMorales Segura, Raúl 
Authordc.contributor.authorLeiva Guzmán, Manuel 
Admission datedc.date.accessioned2019-03-18T11:53:38Z
Available datedc.date.available2019-03-18T11:53:38Z
Publication datedc.date.issued2015
Cita de ítemdc.identifier.citationEnvironment International, Volumen 82,
Identifierdc.identifier.issn01604120
Identifierdc.identifier.other10.1016/j.envint.2015.02.009
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/166681
Abstractdc.description.abstract© 2015 Elsevier Ltd. A critical analysis of Chile's National Air Quality Information System (NAQIS) is presented, focusing on particulate matter (PM) measurement. This paper examines the complexity, availability and reliability of monitoring station information, the implementation of control systems, the quality assurance protocols of the monitoring station data and the reliability of the measurement systems in areas highly polluted by particulate matter. From information available on the NAQIS website, it is possible to confirm that the PM2.5 (PM10) data available on the site correspond to 30.8% (69.2%) of the total information available from the monitoring stations. There is a lack of information regarding the measurement systems used to quantify air pollutants, most of the available data registers contain gaps, almost all of the information is categorized as "preliminary information" and neither standard operating procedures (operational and validation) nor assurance audits or quali
Lenguagedc.language.isoen
Publisherdc.publisherElsevier Ltd
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/
Sourcedc.sourceEnvironment International
Keywordsdc.subjectBeta attenuation monitoring
Keywordsdc.subjectChilean air quality system
Keywordsdc.subjectParticulate matter
Keywordsdc.subjectQuality control
Títulodc.titleAccuracy and reliability of Chile's National Air Quality Information System for measuring particulate matter: Beta attenuation monitoring issue
Document typedc.typeArtículo de revista
Catalogueruchile.catalogadorSCOPUS
Indexationuchile.indexArtículo de publicación SCOPUS
uchile.cosechauchile.cosechaSI