Show simple item record

Authordc.contributor.authorFariña Sirandoni, Rodrigo 
Authordc.contributor.authorGonzález Rocabado, Andrea 
Authordc.contributor.authorToledo Pinto, Ximena 
Authordc.contributor.authorVillanueva, Rodrigo 
Authordc.contributor.authorMartínez, Benjamín 
Authordc.contributor.authorPérez, Hernán 
Admission datedc.date.accessioned2019-10-14T15:41:01Z
Available datedc.date.available2019-10-14T15:41:01Z
Publication datedc.date.issued2019
Identifierdc.identifier.issn15363732
Identifierdc.identifier.issn10492275
Identifierdc.identifier.other10.1097/SCS.0000000000005791
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/171510
Abstractdc.description.abstractPURPOSE: To propose a three-dimensional cephalometric analysis of upper airway (UA) related to its functionality, defining normal reference values in healthy individuals and the relationship between nostril, nasal valve, and minimal cross-sectional area (MCS) in functional upper airway. MATERIALS AND METHODS: The UAs of 20 Class I patients were analyzed with CBCT using Nemoceph 3D-OS and HOROS software, determining linear distances, volumes and cross-sectional areas, including MCS. RESULTS: MCS was mostly located in the middle-upper oropharynx and high hypopharynx. MCS showed moderate correlation with the area of both nares (BNA) (r = 0.60, P = 0.004) and high correlation with the area of both internal nasal valves (BNV) (r = 0.66, P = 0.0016). BNA and BNV showed a moderate correlation (r = 0.445, P = 0.049). A total upper airway (TUA) and functional upper airway (FUA) volumes were established. TUA and FUA showed the strongest statistical correlation (r = 0.82, P = 0.00). A paired samples t test compared the measurement as absolute values of MCS with BNA (t = 0.781, P = 0.44), with BNV (t = -0.12, P = 0.90); and BNA with BNV (t = -0.76, P = 0.45), showed no significant differences. CONCLUSIONS: A functional cephalometric analysis of the UA with stable parameters in cervical spine and normal reference values has been proposed. BNA and BNV could be used as reference to establish the MCS compatible with respiratory health.
Lenguagedc.language.isoen
Publisherdc.publisherLippincott Williams and Wilkins
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile
Sourcedc.sourceJournal of Craniofacial Surgery
Keywordsdc.subjectCephalometry
Keywordsdc.subjectCone beam computed tomography
Keywordsdc.subjectObstructive sleep apnea syndrome
Keywordsdc.subjectUpper airway
Títulodc.titleRelationship between Nostril, Nasal Valve and Minimal Cross-Sectional Area in Functional Upper Airway
Document typedc.typeArtículo de revista
dcterms.accessRightsdcterms.accessRightsAcceso a solo metadatos
Catalogueruchile.catalogadorlaj
Indexationuchile.indexArtículo de publicación SCOPUS
uchile.cosechauchile.cosechaSI


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record