The difference between first and second harmonic amplitudes correlates between glottal airflow and neck-surface accelerometer signals during phonation
Artículo

Open/ Download
Access note
Acceso Abierto
Publication date
2019Metadata
Show full item record
Cómo citar
Mehta, Daryush D.
Cómo citar
The difference between first and second harmonic amplitudes correlates between glottal airflow and neck-surface accelerometer signals during phonation
Author
Abstract
Miniature high-bandwidth accelerometers on the anterior neck surface are used in laboratory and ambulatory settings to obtain vocal function measures. This study compared the widely applied L1-L2 measure (historically, H1-H2) - the difference between the log-magnitude of the first and second harmonics - computed from the glottal airflow waveform with L1-L2 derived from the raw neck-surface acceleration signal in 79 vocally healthy female speakers. Results showed a significant correlation (r = 0.72) between L1-L2 values estimated from both airflow and accelerometer signals, suggesting that raw accelerometer-based estimates of L1-L2 may be interpreted as reflecting glottal physiological parameters and voice quality attributes during phonation.
Indexation
Artículo de publicación SCOPUS
Identifier
URI: https://repositorio.uchile.cl/handle/2250/172553
DOI: 10.1121/1.5100909
ISSN: 00014966
Quote Item
Journal of the Acoustical Society of America, Volumen 145, Issue 5, 2019, Pages EL386-EL392
Collections