Peripheral venoarterial extracorporeal membrane oxygenation for periprocedural Cardiogenic shock during interventional cardiology
Author
dc.contributor.author
Verdugo, Fernando J.
Author
dc.contributor.author
Cataldo, Pabla
Author
dc.contributor.author
Sandoval, Jorge
Author
dc.contributor.author
Pineda, Fernando
Author
dc.contributor.author
Dauvergne, Christian
Author
dc.contributor.author
Duarte, Manuel
Author
dc.contributor.author
Bonta, Camila
Author
dc.contributor.author
Iturra, Sebastián
Author
dc.contributor.author
Olivares, Gabriel
Author
dc.contributor.author
Concha, Marcelo
Author
dc.contributor.author
Rossel, Víctor
Admission date
dc.date.accessioned
2021-07-01T23:34:21Z
Available date
dc.date.available
2021-07-01T23:34:21Z
Publication date
dc.date.issued
2020
Cita de ítem
dc.identifier.citation
Rev Med Chile 2020; 148: 1295-1301
es_ES
Identifier
dc.identifier.issn
0034-9887
Identifier
dc.identifier.uri
https://repositorio.uchile.cl/handle/2250/180362
Abstract
dc.description.abstract
Background: Cardiogenic shock (CS) is uncommon in the cardiac catheterization
laboratory (CCL) among patients undergoing coronary angiography.
Periprocedural CS is more frequent in high-risk patients and in technically
demanding procedures. Aim: To describe the clinical outcomes of patients who
underwent peripheral venoarterial extracorporeal membrane oxygenation
(pVA-ECMO) for CS associated with interventional cardiology procedures. Material
and Methods: Review of clinical records of seven patients treated between
January 2014 and October 2018. Results: pVA-ECMO was implanted within 6
hours of the interventional cardiology procedure. All patients had coronary artery
disease and one of them also had symptomatic severe aortic stenosis. One patient
entered the CCL in cardiac arrest. Percutaneous coronary intervention (PCI)
was performed in all patients; four patients underwent an emergency procedure
and five patients experienced PCI complications. One patient undergoing transcatheter
aortic valve replacement suffered acute severe aortic regurgitation. An
intra-aortic balloon pump was inserted at the CCL in five patients. Six patients
experienced cardiac arrest. Mean SAVE score was -4.3 and baseline lactate
55 mg/dl. pVA-ECMO mean duration was 5 ± 4 days. Survival after both
hospital discharge and 12 months of follow-up was 85.7% Regarding vascular
access complications, we observed one access site hematoma and one episode of
cannulation site bleeding requiring surgical repair. Conclusions: pVA-ECMO
should be considered in patients with periprocedural CS as a bridge to recovery.
Its use was associated with improved clinical outcomes in this series.
es_ES
Abstract
dc.description.abstract
Antecedentes: El shock cardiogénico (SC) es infrecuente en el laboratorio
de cateterismo cardíaco (LCC) entre pacientes que son sometidos a coronariografía.
El SC peri-procedimiento es más frecuente en pacientes de alto riesgo y en procedimientos técnicamente complejos. Objetivos: Describir los resultados
clínicos de pacientes que fueron conectados a oxigenación con membrana extracorpórea
veno-arterial periférica (ECMO-VAp) por SC peri-procedimiento
de cardiología intervencional. Material y Métodos: Revisión de fichas clínicas
de siete pacientes tratados en nuestro centro desde enero de 2014 a octubre de
2018. Resultados: ECMO-VAp fue utilizado dentro de las primeras 6 horas
del procedimiento. Todos los pacientes tenían enfermedad coronaria y uno de
ellos tenía además estenosis aórtica severa. Un paciente ingresó al LCC en paro
cardíaco. Una intervención coronaria percutánea (ICP) fue realizada en todos
los pacientes; 4 se realizaron procedimientos de emergencia y 5 pacientes tuvieron
complicaciones de la ICP. A un paciente se le realizó un reemplazo valvular
aórtico percutáneo y desarrolló una insuficiencia valvular aórtica aguda severa.
Se instaló un balón de contrapulsación en el LCC en 5 pacientes. Seis pacientes
tuvieron un paro cardiorrespiratorio. El valor del score de SAVE fue de -4,3 y
el lactato basal 55 mg/dL. La duración media del ECMO-VAp fue 5 ± 4 días.
La sobrevida al alta y a los 12 meses fue 85,7%. Como complicaciones del sitio
de acceso vascular se observaron 1 hematoma y un episodio de sangrado que
requirió reparación quirúrgica. Conclusiones: ECMO-VAp debería ser considerado
en pacientes con SC peri-procedimiento como un puente a recuperación;
su utilización estuvo asociada con mejoría de resultados clínicos en esta serie