A new rotating-disk sorptive extraction mode, with a copolymer of divinylbenzene and N-vinylpyrrolidone trapped in the cavity of the disk, used for determination of florfenicol residues in porcine plasma
Artículo
Publication date
2014Metadata
Show full item record
Cómo citar
Cañas, Alejandro
Cómo citar
A new rotating-disk sorptive extraction mode, with a copolymer of divinylbenzene and N-vinylpyrrolidone trapped in the cavity of the disk, used for determination of florfenicol residues in porcine plasma
Abstract
A novel extraction approach was developed based
on rotating-disk sorptive extraction (RDSE). In this approach
the rotating-disk extraction device consists of a Teflon disk,
with a cavity that is loaded with a commercial sorbent phase
selected according to the polarity of the analyte. To avoid
leakage of the sorbent, the cavity is covered with a fiberglass
filter and sealed with a Teflon ring. The proposed novel
analytical RDSE technique was used in this study to determine
florfenicol levels in plasma as a model analyte, or sample
system, to describe the pharmacokinetics of a veterinary formulation.
The sorbent used for this application was the copolymer
of divinylbenzene and N-vinylpyrrolidone (Oasis HLB),
which was selected because the florfenicol molecule contains
both hydrophilic and lipophilic moieties. After the extraction,
final determination of the analyte was performed by HPLC–
DAD. Calibration plots and other analytical features were
obtained after 90 min of extraction. The calibration plot was
linear over the interval 0.4–16 μg mL−1 (n=6), with R2=
0.9999. Recovery and repeatability were determined using a
blank plasma sample spiked with 4.8 μg mL−1 florfenicol. A
recovery of 91.5 %, with a relative standard deviation (RSD)
of 8.8 %, was obtained when the extraction was evaluated
using six different rotating-disk devices. Precision was also
assessed, using the same disk (containing the same sorbent
phase) for eight aliquots of the same sample. The RSD under
these conditions was 10.2 %, clearly indicating that the sorptive
phase could possibly be re-used. Accordingly, RDSE is a
suitable sample preparation alternative to liquid–liquid extraction
(LLE), solid-phase extraction (SPE), and stir-bar sorptive
extraction (SBSE).
General note
Artículo de publicación ISI
Patrocinador
FONDECYT
(project 1100085) for financial support.
Identifier
URI: https://repositorio.uchile.cl/handle/2250/121872
DOI: DOI: 10.1007/s00216-014-7628-8
Quote Item
Anal Bioanal Chem (2014) 406: 2205–2210
Collections