Show simple item record

Professor Advisordc.contributor.advisorKremer F., Cristian
Professor Advisordc.contributor.advisorSeguel S., Oscar
Authordc.contributor.authorCandia Antich, Rodrigo Alejandro 
Associate professordc.contributor.otherHaberland A., Julio
Associate professordc.contributor.otherPeppi A., Cecilia
Admission datedc.date.accessioned2018-05-15T21:59:36Z
Available datedc.date.available2018-05-15T21:59:36Z
Publication datedc.date.issued2013
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/147795
General notedc.descriptionMemoria para optar al Título Profesional de: Ingeniero Agrónomoes_ES
Abstractdc.description.abstractLa necesidad de monitorear el estado hídrico del suelo ha llevado al desarrollo de distintas técnicas que estiman el contenido de agua ( ) de éste Dentro de estas técnicas existen dispositivos que utilizan impulsos electromagnéticos, estimando en base a la permisividad dieléctrica del suelo ( a); sin embargo, existe un efecto de las sales que generan errores en la medición realizada. Esto hace necesario realizar una calibración de los sensores para poder representar de buena manera el estado hídrico en suelos con altos contenidos salinos. Este ensayo fue realizado en tres predioss en el Valle de Copiapó, con texturas predominantemente finas y valores de conductividad eléctrica saturada entre 4,4 a 16,5 dS m-1. Se calibraron para estas condiciones 2 sensores del tipo FDR (POGO y Diviner 2000) y 1 del tipo TDR (GS3). Con las calibraciones de fábrica de estos sensores, el error estándar asociado a la estimación de fue de 0,053 m3 m-3, 0,086 m3 m-3 y 0,070 m3 m-3, para los sensores GS3, POGO y Diviner 2000 respectivamente. Luego de la calibración estos errores disminuyeron a 0,033 m3 m-3, 0,063 m3 m-3 y 0,019 m3 m-3. No fue necesaria la realización de curvas de calibración diferenciadas en rangos de salinidad ni de , a excepción del sensor Diviner 2000, en donde se realizó un ajuste para cada profundidad y cada suelo muestreado.es_ES
Abstractdc.description.abstractThe need to monitor soil hydric status has promoted the development of different techniques to estimate the soil water content (θ). Among those techniques there are devices that work with electromagnetic pulses to estimate θ based on the soil dielectric permittivity ( a), however, soil salt content can affect the measurements and cause errors on the soil water estimation. Based on this, it is necessary to calibrate these sensors to determine in a proper way the soil hydric status in soils with high salt content. This trial was developed at the Copiapo Valley in three predominantly fine textured soils with saturated electrical conductivity ranging from 4.4 to 16.5 dS m-1. Under these conditions 2 FDR types sensors (POGO and Diviner 2000) and 1 TDR type (GS3) were calibrated. Under the original settings the standard error of the θ estimation were 0.053 m3 m- 3, 0.086 m3 m-3 and 0.070 m3 m-3 for the GS3, POGO and Diviner respectively. Once the custom calibration was set up the standard error were a 0.033 m3 m-3, 0.063 m3 m-3 and 0.019 m3 m-3. The calibration grouped according to salinity or θ ranges was not necessary, except for the Diviner 2000 sensor where calibration for each depth and soil tested was necessary.es_ES
Lenguagedc.language.isoeses_ES
Publisherdc.publisherUniversidad de Chilees_ES
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile*
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/*
Keywordsdc.subjectSensoreses_ES
Keywordsdc.subjectHumedad de sueloses_ES
Keywordsdc.subjectSuelos salinoses_ES
Títulodc.titleCalibración de dos sensores del tipo FDR y un sensor TDR en distintas condiciones de salinidad del sueloes_ES
Title in another languagedc.title.alternativeCalibration of two fdr type sensors and one tdr type sensor on different soil salinity conditionses_ES
Document typedc.typeTesis
Catalogueruchile.catalogadorrgfes_ES
Departmentuchile.departamentoEscuela de Pregradoes_ES
Facultyuchile.facultadFacultad de Ciencias Agronómicases_ES


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Chile
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile