Show simple item record

Professor Advisordc.contributor.advisorEscalona C., Víctor
Professor Advisordc.contributor.advisorPrieto D., Carmen
Authordc.contributor.authorSánchez Bobadilla, Claudia Francisca 
Associate professordc.contributor.otherChiffelle G, Ítalo
Associate professordc.contributor.otherSeguel S., Oscar
Admission datedc.date.accessioned2018-05-31T15:47:05Z
Available datedc.date.available2018-05-31T15:47:05Z
Publication datedc.date.issued2013
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/148412
General notedc.descriptionMemoria para optar al Título Profesional de Ingeniero Agrónomoes_ES
Abstractdc.description.abstractLos productos mínimamente procesados en fresco (MPF) están listos para consumir, es por esto que su higienización es la principal etapa, donde el sanitizante más usado es hipoclorito de sodio (NaClO). Este sanitizante podría generar residuos y la posible formación de compuestos cancerígenos, por esto la industria de alimentos MPF está buscando nuevas alternativas más amigables con el medio ambiente y para la salud humana. En este sentido, la sanitización con radiación UV-C es un método que no deja residuos en el alimento, en combinación con el uso de atmósfera modificada, las hortalizas se mantienen con una baja respiración, alargando su vida útil. El objetivo de este trabajo fue evaluar el efecto de la radiación UV-C sobre la tasa respiratoria y la carga microbiana de hojas de berros MPF. Para esto se utilizaron berros hidropónicos tratados con 5 dosis de UV-C de 0,34 a 20,13 kJ m- ² y un tratamiento con hipoclorito de sodio (100 mg L-1 ) como testigo. Todos los tratamientos fueron envasados en atmósfera modificada y almacenados a 5 ºC durante 10 días. Se evaluaron los parámetros de respiración, concentración de gases en las bolsas, color, recuento microbiológico y parámetros sensoriales. Las hojas de berros tratados con 20,13 kJ m-2 de radiación UV-C presentaron la tasa respiratoria más baja que el resto de los tratamientos aplicados, con 23,4 mg CO2 kg-1 h -1 . Sin embargo, esta dosis, no fue efectiva en la reducción de la carga microbiana. Tras 10 días de almacenamiento, los recuentos de aerobios mesófilos más bajos se obtuvieron con dosis de 10,15 y 15,14 kJ m-2 , siendo de 4,3 y 4,5 log UFC g-1 respectivamente, en tanto, que 20,13 kJ m- ², presentó la mayor carga, 7,8 log UFC g-1 . Los tratamientos con UV-C obtuvo resultados de color y análisis sensorial similar al NaClO 100 mg L-1 , por tanto la UV-C surge como una buena alternativa como tratamiento sanitizante en hojas de berros.es_ES
Abstractdc.description.abstractThe fresh-cut vegetable (MPF) are ready to consume, reason why the sanitization is the main stage, where the most widely used sanitizer is sodium hypochlorite (NaClO). This sanitizer could generate waste and the possible formation of carcinogenic compounds, so the food industry is looking for new alternatives MPF friendlier to the environment and to human health. In this sense, the sanitization with UV-C is a method that leaves no residue in the food and, in combination with the use of modified atmosphere, vegetables remain a low breath, extending its life. The aim of this study was to evaluate the effect of UV-C radiation on respiration rate and microbial load MPF watercress leaves. This was used for hydroponic watercress treated with 5 doses of UV-C from 0.34 to 20.13 kJ m- ² and a treatment with sodium hypochlorite (100 mg L-1 ) as a control. All treatments were modified atmosphere packaged and stored at 5 ° C for 10 days. Parameters were evaluated breathing, concentration of gases in the bags, color, microbiological counts and sensory parameters. Watercress leaves treated with 20.13 kJ m-2 UV-C had respiratory rate lower than the rest of the treatments applied with 23.4 mg CO2 kg-1 h -1 . However, this dose, was not effective in reducing microbial load. After 10 days of storage, mesophilic aerobic counts were obtained with doses of 10.15 and 15.14 kJ m-2 , with 4.3 and 4.5 log cfu g-1 respectively, and that 20.13 kJ m-² had the highest, 7.8 log cfu g-1 . The treatment with UV-C and scored color NaClO sensory analysis similar to 100 mg L-1 , therefore the UV-C emerges as a good alternative for treatment in watercress leaves sanitizer.es_ES
Lenguagedc.language.isoeses_ES
Publisherdc.publisherUniversidad de Chilees_ES
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile*
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/*
Keywordsdc.subjectBerroes_ES
Keywordsdc.subjectAlmacenamiento en fríoes_ES
Keywordsdc.subjectRadiación ultravioletaes_ES
Keywordsdc.subjectHipoclorito de sodioes_ES
Keywordsdc.subjectNasturtium officinalees_ES
Títulodc.titleAplicación de radiación UV-C sobre hojas de berro (Nasturtium officinale R. Br.) mínimamente procesado conservado bajo atmósfera modificadaes_ES
Title in another languagedc.title.alternativeAplication of UV-C radiation on leaves of watercrees (Nasturtium officinale R. Br.) minimal processing preserv under modified atmospherees_ES
Document typedc.typeTesis
Catalogueruchile.catalogadorrgfes_ES
Departmentuchile.departamentoEscuela de Pregradoes_ES
Facultyuchile.facultadFacultad de Ciencias Agronómicases_ES


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Chile
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile