Professor Advisor | dc.contributor.advisor | Richter Duk, Pablo | |
Author | dc.contributor.author | Ulisse Ulisse, Karla | |
Staff editor | dc.contributor.editor | Facultad de Ciencias Químicas y Farmacéuticas | |
Staff editor | dc.contributor.editor | Departamento de Química Inorgánica y Analítica | |
Admission date | dc.date.accessioned | 2014-10-28T21:03:35Z | |
Available date | dc.date.available | 2014-10-28T21:03:35Z | |
Publication date | dc.date.issued | 2014 | |
Identifier | dc.identifier.uri | https://repositorio.uchile.cl/handle/2250/117243 | |
General note | dc.description | Memoria para optar al título de Químico | en_US |
Abstract | dc.description.abstract | Los llamados contaminantes emergentes, están presentes en un variado rango de productos de la vida cotidiana, como los productos farmacéuticos que son liberados de manera indiscriminada a las plantas de tratamiento de aguas, donde al no ser removidos en su totalidad tienden a permanecer en la fase acuosa, y por lo tanto, son frecuentemente detectados en aguas superficiales. La preocupación recae en que sus productos de degradación pueden ser incluso más tóxicos que los contaminantes iniciales.
Entre los productos farmacéuticos, las drogas antiinflamatorias no esteroidales (non-steroidal anti-inflammatory drugs) (NSAIDs), han sido detectadas frecuentemente en el medio ambiente y no poseen una legislación que las regule. Es por esto que se desarrolló un método analítico para determinar la concentración de estos fármacos más comúnmente usados en muestras acuosas, mediante la técnica de microextracción por sorción en disco rotatorio (rotating disk sorptive extraction) (RDSE). El dispositivo de extracción es de teflón y presenta una cavidad en el cual se le inmoviliza un polímero de impresión molecular (MIP) como sorbente selectivo para la extracción de los analitos, con la posterior cuantificación mediante cromatografía gaseosa acoplada a espectrometría de masas (CG-MS), con previo proceso de derivatización de los extractos provenientes de RDSE.
Las condiciones de extracción optimizadas para los antinflamatorios no esteroidales, ácido mefenámico y diclofenaco fueron las siguientes: volumen de muestra de 50 mL, 25 mg de fase MIP, agitación a 3000 rpm, tiempo de extracción de 60 minutos, pH 2 y un proceso de desorción con 10 mL de metanol por 5 minutos. Se demostró que para los fármacos en estudio la fase sorbente de MIP extrae en promedio 3 veces más que la fase con el mismo polímero no impreso (NIP), dejando de manifiesto el efecto de las cavidades de la molécula impresa. La metodología propuesta se validó en una matriz de agua potable.
El método alcanzó límites de detección entre 0,060 - 0,223 μgL-1 de AINEs con recuperaciones entre 99-100% ± 5-6%. La aplicación en muestras de aguas residuales obtenidas de una planta de tratamiento de Santiago entregó concentraciones para estos fármacos entre 1,8 - 4,3 μgL-1 en el afluente y de
1,3 – 2,8 en el efluente | en_US |
Abstract | dc.description.abstract | The so called emerging contaminants are present in a wide range of daily life products such as drugs that are haphazardly released into water treatment plants where, as they are not completely removed, they tend to remain in the aqueous phase and consequently are found in surface waters. The concern lies in that they can transform into products that are more toxic and more dangerous than the original contaminants.
Non-steroidal anti-inflammatory drugs (NSAIDs) are a type of drugs that have been frequently detected in the environment and are not regulated by law. For this reason, an analytical method was developed to determine the concentration of the most commonly used NSAIDs in aqueous samples, using the rotating-disk sorptive microextraction technique (RDSE). The extraction device, made of Teflon, contains a cavity in which it can immobilize a molecularly imprinted polymer (MIP) as a selective sorbent for extracting analytes, which are subsequently quantified using the gas chromatography-mass spectrometry (GC-MS) method once the extracts from RDSE were subject to a derivatization process.
The optimal condition for extraction of the mefenamic acid and diclofenac NSAIDs were the following: sample volume of 50 mL, 25 mg of MIP, 3000 rpm agitation, extraction time 60 min, pH2 and desorption with 10 mL of methanol during 5 minutes.
For the drugs under study, it was shown that the sorbent phase of MIP recovered on average three times more than the same phase with no imprinted polymer (NIP), evidencing the effect of the cavities of the imprinted molecule. The proposed methodology was validated using a potable water matrix The method achieved NSAIDs detection limits between 0.060 to 0.223 ugL-1 with recoveries between 99-100% ± 5-6%. The application (of this method) to waste water samples obtained from a water treatment plant in Santiago showed NSAIDs concentrations of 1.8 to 4.3 μgL-1 in the influent stream and 1.3 to 2.8 μgL-1 in the effluent stream | |
Lenguage | dc.language.iso | es | en_US |
Publisher | dc.publisher | Universidad de Chile | en_US |
Keywords | dc.subject | Antiinflamatorios no esteroideos | en_US |
Keywords | dc.subject | Agentes antiinflamatorios-Aspectos ambientales | en_US |
Keywords | dc.subject | Extracción (Química) | en_US |
Título | dc.title | Microextracción de fármacos antiinflamatorios no esteroidales desde matrices acuosas usando polímero de impresión molecular inmovilizado en un sistema de disco rotatorio | en_US |
Document type | dc.type | Tesis | |