Ionic liquids for improving the extraction of NSAIDs in water samples using dispersive liquid-liquid microextraction by high performance liquid chromatography-diode array-fluorescence detection
Artículo
Publication date
2015Metadata
Show full item record
Cómo citar
Toledo Neira, Carla
Cómo citar
Ionic liquids for improving the extraction of NSAIDs in water samples using dispersive liquid-liquid microextraction by high performance liquid chromatography-diode array-fluorescence detection
Abstract
A rapid, sensitive and efficient analytical method based on the use of ionic liquids for determination of non-steroidal anti-inflammatory drugs (NSAIDs) in water samples was developed. High-performance liquid chromatography equipped with a diode array and fluorescence detector was used for quantification of ketoprofen, ibuprofen and diclofenac in tap and river water samples. This new method relies on the use of two ionic liquids with multiple functionalities: one functions as an extraction solvent (1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF6]), and the other changes the polarity in the aqueous medium (1-butyl-3-methylimidazolium tetrafluoroborate, ([BMIM[BF4]). Factors such as the type and volume of the ILs and dispersive solvent, sample volume, and centrifugation time were investigated and optimized. The optimized method exhibited good precision, with relative standard deviation values between 2% and 3%, for the three NSAIDs. Limits of detection achieved for all of the analytes were between 17 and 95 ng mL(-1), and the recoveries ranged from 89% to 103%. Furthermore, the enrichment factors ranged from 49 to 57. The proposed method was successfully applied to the analysis of NSAIDs in tap and river water samples.
Indexation
Artículo de publicación SCOPUS
Identifier
URI: https://repositorio.uchile.cl/handle/2250/158351
DOI: 10.1016/j.talanta.2014.11.067
ISSN: 00399140
Quote Item
Talanta, Volumen 134, 2015, 619-626.
Collections
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile
Related items
Showing items related by title, author, creator and subject.
-
Toledo, Carla; Valle, Luis; Narváez, Jessica; Richter Duk, Pablo (SOC BRASILEIRA QUIMICA, 2007)A rapid and simple method was developed for screening polychlorinated biphenyls in transformer oil. The method is based on liquid-liquid extraction in methanol and subsequent direct gas chromatography-mass spectrometric ...
-
Toral Ponce, María; Manríquez, Roberto; Richter Duk, Pablo (MARCEL DEKKER INC, 1999)A simple flow injection photometric method for the determination of copper was developed based on the formation and liquid-liquid extraction of the analyte-bathocuproine-perchlorate ternary complex. The analytical reaction ...
-
Kasch, N.; Dierking, I.; Turner, M.; Romero Hasler, P.; Soto Bustamante, Eduardo (Royal Soc Chemistry, 2015)A small fraction of an acrylate liquid crystalline monomer (<= 5%) is mixed into nematic and smectic liquid crystalline phases, and polymerised through the application of a voltage (electropolymerisation). Polarising ...