Randomized trial of early bubble continuous positive airway pressure for very low birth weight infants
Artículo
Open/ Download
Publication date
2012Metadata
Show full item record
Cómo citar
Tapia, Jose L.
Cómo citar
Randomized trial of early bubble continuous positive airway pressure for very low birth weight infants
Author
Abstract
Objective: To determine whether very low birth weight infants (VLBWIs), initially supported with continuous positive airway pressure (CPAP) and then selectively treated with the INSURE (intubation, surfactant, and extubation to CPAP; CPAP/INSURE) protocol, need less mechanical ventilation than those supported with supplemental oxygen, surfactant, and mechanical ventilation if required (Oxygen/mechanical ventilation [MV]). Study design: In a multicenter randomized controlled trial, spontaneously breathing VLBWIs weighing 800-1500 g were allocated to receive either therapy. In the CPAP/INSURE group, if respiratory distress syndrome (RDS) did not occur, CPAP was discontinued after 3-6 hours. If RDS developed and the fraction of inspired oxygen (FiO 2) was >0.35, the INSURE protocol was indicated. Failure criteria included FiO 2 >0.60, severe apnea or respiratory acidosis, and receipt of more than 2 doses of surfactant. In the Oxygen/MV group, in the presence of RDS, supplemental oxygen wi
Indexation
Artículo de publicación SCOPUS
Identifier
URI: https://repositorio.uchile.cl/handle/2250/165559
DOI: 10.1016/j.jpeds.2011.12.054
ISSN: 00223476
10976833
Quote Item
Journal of Pediatrics, Volumen 161, Issue 1, 2018,
Collections