Envelope analysis of the airflow signal to improve polysomnographic assessment of sleep disordered breathing
Artículo
Open/ Download
Access note
Acceso Abierto
Publication date
2014Metadata
Show full item record
Cómo citar
Diaz, Javier A.
Cómo citar
Envelope analysis of the airflow signal to improve polysomnographic assessment of sleep disordered breathing
Abstract
Study Objectives: Given the detailed respiratory waveform signal provided by the nasal cannula in polysomnographic (PSG) studies, to quantify sleep breathing disturbances by extracting a continuous variable based on the coefficient of variation of the envelope of that signal. Design: Application of an algorithm for envelope analysis to standard nasal cannula signal from actual polysomnographic studies. Setting: PSG recordings from a sleep disorders center were analyzed by an algorithm developed on the Igor scientific data analysis software. Patients or Participants: Recordings representative of different degrees of sleep disordered breathing (SDB) severity or illustrative of the covariation between breathing and particularly relevant factors and variables. Interventions: The method calculated the coefficient of variation of the envelope for each 30-second epoch. The normalized version of that coefficient was defined as the respiratory disturbance variable (RDV). The method outcome was
Indexation
Artículo de publicación SCOPUS
Identifier
URI: https://repositorio.uchile.cl/handle/2250/166064
DOI: 10.5665/sleep.3338
ISSN: 01618105
15509109
Quote Item
Sleep, Volumen 37, Issue 1, 2018, Pages 199-208