Abstract | dc.description.abstract | El uso de sensores de calidad de aire de bajo costo podría aumentar la resolución
espacio-temporal del monitoreo tradicional, proporcionando una gran cantidad de
información en tiempo real, gracias al uso de internet. Aprovechar las oportunidades que
entregan los sensores requiere comprender sus limitaciones. La respuesta de los
sensores se ve afectada por factores ambientales, lo que hace necesario optimizar su
desempeño mediante la aplicación de un algoritmo de ajuste que incorpore las variables
interferentes, como temperatura, humedad relativa y/o gases de interferencia cruzada.
En este trabajo se desarrolló una metodología de ajuste para las mediciones de
sensores de NO2 y SO2, y se evaluó su desempeño mediante su ubicación conjunta con
instrumentos de monitoreo regulatorio. Se dispuso de cuatro sensores de NO2 y dos de
SO2, los que fueron utilizados en tres campañas de monitoreo. La primera campaña se
realizó en la Estación de Monitoreo de Calidad del Aire (EMCA) La Florida y cumplió con
el objetivo de comparar los sensores bajo las mismas condiciones ambientales. En la
segunda, los sensores se trasladan a las EMCA Quintero, Ventanas y Valle Alegre,
donde se evaluó su comportamiento en un área urbana-industrial. En la tercera
campaña, se trasladan los sensores a EMCA cercanas y con similares condiciones
ambientales con el objeto de evaluar el ajuste de los modelos obtenidos en la campaña
anterior El ajuste se realizó empleando el modelo de regresión lineal múltiple, en el que
se incorporaron las variables de temperatura del sensor y humedad ambiental. Fue
necesario dividir en tres secciones los datos obtenidos en cada campaña, según
temperatura y voltaje para los sensores NO2 y SO2 respectivamente, al objeto de cumplir
con los supuestos del modelo.
La comparación mutua de los sensores indica que el funcionamiento individual
depende de su sensibilidad intrínseca a factores ambientales. La metodología de
segmentación permitió ajustar la respuesta de los sensores en un amplio rango de
variabilidad ambiental de temperatura y humedad (NO2: R2 > 0,6 – SO2: R2 > 0,98). El
desempeño de los sensores de NO2 empeora al ser trasladados de un área urbana (R2
> 0,8; sesgo < 15%) a una urbana-industrial (R2 > 0,6; sesgo > 30%). Los sensores de
SO2 solo se evaluaron en Quintero, en donde su ajuste fue mayor a 0,9, debido a que
las altas concentraciones ambientales coinciden con los altos voltajes medidos. Al
evaluar los ajustes obtenidos en la campaña anterior en otro sitio con similares
características se concluye que estos se ajustan correctamente para los sensores de
SO2 (R2 > 0,8). Sin embargo, para los sensores de NO2 los ajustes logrados al comparar
con los instrumentos de referencia fueron bajos (R2 < 0,3).Se concluye que, el entorno de evaluación de los sensores de SO2 y su menor
dependencia a factores ambientales, garantiza el buen desempeño de estos para la
detección de episodios de altas concentraciones en un área urbana-industrial. Por otra
parte, la fuerte dependencia de los sensores de NO2 a factores ambientales conduce a
la necesidad de reajuste de sus mediciones en cada sitio de monitoreo. | es_ES |
Abstract | dc.description.abstract | The use of low-cost air quality sensors could increase the spatial-temporal
resolution of traditional monitoring, providing a large amount of information in real-time,
thanks to the use of the Internet. Taking advantage of the opportunities offered by
sensors requires understanding their limitations. The response of the sensors is affected
by environmental factors, which makes it necessary to optimize their performance by
applying an adjustment algorithm that incorporates interfering variables, such as
temperature, relative humidity and/or cross-interference gases.
In the present work, an adjustment methodology was developed for the
measurements of the NO2 and SO2 sensors, and their performance was evaluated
through their joint location with regulatory monitoring instruments. Four NO2 and 2 SO2
sensors were available, which were used in 3 monitoring campaigns. The first campaign
was conducted at the Florida Air Quality Monitoring Station (EMCA) and met the objective
of comparing the sensors under the same environmental conditions. In the second, the
sensors are transferred to EMCA Quintero, Ventanas and Valle Alegre, where their
behavior was evaluated in an urban-industrial area. In the third campaign, the sensors
are transferred to EMCA frequently and with similar environmental conditions in order to
assess the fit of the models detected in the previous campaign The adjustment was made using the multiple linear regression model, in which
the variables of sensor temperature and ambient humidity were incorporated. It was
necessary to divide the data obtained in each campaign into 3 sections, according to the
temperature and voltage of the NO2 and SO2 sensors, respectively, to comply with the
assumptions of the model.
The mutual comparison of the sensors indicates that the individual operation depends on
its intrinsic sensitivity to environmental factors. The segmentation methodology allowed
the sensor response to be adjusted over a wide range of ambient temperature and
humidity variability (NO2: R2> 0,6 - SO2: R2> 0,98). The performance of NO2 sensors
worsens when they move from an urban area (R2> 0,8; bias <15%) to an urban-industrial
one (R2> 0,6; bias> 30%). The SO2 sensors were only evaluated in Quintero, where their
adjustment was greater than 0,9, because the high environmental concentrations
coincide with the high measured voltages. The spatial transfer capability of the
configuration works correctly for SO2 sensors (R2> 0,8). However, for the NO2 sensors
the adjustments achieved when comparing with the reference instruments were low (R2
<0,3).
It is concluded that the evaluation environment of the SO2 sensors and their lower
dependence on environmental factors, guarantees their good performance for the
detection of episodes of high concentrations in an urban-industrial area. On the other
hand, the strong dependence of NO2 sensors on environmental factors leads to the need
to readjust their measurements at each monitoring site. | es_ES |
Lenguage | dc.language.iso | es | es_ES |
Publisher | dc.publisher | Universidad de Chile | es_ES |
Keywords | dc.subject | Sensores | es_ES |
Keywords | dc.subject | Contaminación ambiental | es_ES |
Keywords | dc.subject | Monitoreo ambiental | es_ES |
Keywords | dc.subject | Polución ambiental | es_ES |
Título | dc.title | Evaluación del desempeño de los sensores electroquímicos de SO2 y NO2 utilizando instrumentos de monitoreo regulatorio | es_ES |
Document type | dc.type | Tesis | |
dcterms.accessRights | dcterms.accessRights | Acceso abierto | |
Cataloguer | uchile.catalogador | lls | es_ES |
Department | uchile.departamento | Escuela de Pregrado | es_ES |
Faculty | uchile.facultad | Facultad de Ciencias | es_ES |