Dyspnoea and respiratory muscle ultrasound to predict extubation failure
Artículo
Open/ Download
Access note
Acceso abierto
Publication date
2021Metadata
Show full item record
Cómo citar
Dres, Martin
Cómo citar
Dyspnoea and respiratory muscle ultrasound to predict extubation failure
Author
- Dres, Martin;
- Similowski, Thomas;
- Goligher, Ewan C.;
- Pham, Tai;
- Sergenyuk, Liliya;
- Telias, Irene;
- Grieco, Domenico Luca;
- Ouechani, Wissale;
- Junhasavasdikul, Detajin;
- Sklar, Michael C.;
- Damiani, L. Felipe;
- Melo, Luana;
- Santis, César;
- Degravi, Lauriane;
- Decavele, Maxens;
- Brochard, Laurent;
- Demoule, Alexandre;
Abstract
Background This study investigated dyspnoea intensity and respiratory muscle ultrasound early after extubation to predict extubation failure. Methods The study was conducted prospectively in two intensive care units in France and Canada. Patients intubated for at least 48 h were studied within 2 h after an extubation following a successful spontaneous breathing trial. Dyspnoea was evaluated by a dyspnoea visual analogue scale (Dyspnoea-VAS) ranging from 0 to 10 and the Intensive Care Respiratory Distress Observational Scale (IC-RDOS). The ultrasound thickening fraction of the parasternal intercostal and the diaphragm was measured; limb muscle strength was evaluated using the Medical Research Council (MRC) score (range 0–60). Results Extubation failure occurred in 21 out of 122 enrolled patients (17%). The median (interquartile range (IQR)) Dyspnoea-VAS and IC-RDOS were higher in patients with extubation failure versus success: 7 (4–9) versus 3 (1–5) (p<0.001) and 3.7 (1.8–5.8) versus 1.7 (1.5–2.1) (p<0.001), respectively. The median (IQR) ratio of parasternal intercostal muscle to diaphragm thickening fraction was significantly higher and MRC was lower in patients with extubation failure compared with extubation success: 0.9 (0.4–2.1) versus 0.3 (0.2–0.5) (p<0.001) and 45 (36–50) versus 52 (44–60) (p=0.012), respectively. The thickening fraction of the parasternal intercostal and its ratio to diaphragm thickening showed the highest area under the receiver operating characteristic curve (AUC) for an early prediction of extubation failure (0.81). AUCs of Dyspnoea-VAS and IC-RDOS reached 0.78 and 0.74, respectively. Conclusions Respiratory muscle ultrasound and dyspnoea measured within 2 h after extubation predict subsequent extubation failure.
Patrocinador
French Intensive Care Society
European Respiratory Society
2015 Bernhard Drager Award for Advanced Treatment of ARF of the European Society of Intensive Care Medicine
Assistance Publique Hopitaux de Paris
Fondation pour la Recherche Medicale FDM 20150734498
Mitacs Globalink Sorbonne Universites
Indexation
Artículo de publícación WoS
Quote Item
European Respiratory Journal Volume 58 Issue 5 Article Number 2100002 Nov 1 2021
Collections
The following license files are associated with this item: