Show simple item record

Professor Advisordc.contributor.advisorCasanova Pinto, Manuel Antonio
Professor Advisordc.contributor.advisorTapia Fernández, Yasna Mariela
Authordc.contributor.authorBautista Mamani, Juan Elmer
Associate professordc.contributor.otherPfeiffer Jakob, Marco Matías
Associate professordc.contributor.otherSalazar Guerrero, Osvaldo Alejandro
Admission datedc.date.accessioned2024-08-19T19:31:08Z
Available datedc.date.available2024-08-19T19:31:08Z
Publication datedc.date.issued2020
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/200307
Abstractdc.description.abstractComo alternativa a la medición de la conductividad eléctrica del extracto de pasta saturada (CEe), se midió la conductividad eléctrica (CE) en suspensiones, con 5 repeticiones y distintas relaciones suelo:agua, en siete suelos de Chile Central (cuatro Mollisoles, dos Vertisoles y un Entisol). Se evaluaron las relaciones entre la CEe y la CE en soluciones suelo:agua en base masa/volumen y volumen/volumen en laboratorio (CE1:1 m/v, CE1:2,5 m/v, CE1:5 m/v, CE1:1 v/v, CE1:2,5v/v, CE1:5v/v,), así como también volumen/volumen en terreno o in situ (CE1:1 v/v is, CE1:2,5 v/v is, CE1:5 v/v is). Se evaluó también la relación entre las distintas CE medidas y algunas propiedades de los suelos (textura, pH, contenido de agua a saturación, a 33 y a 1500 kPa). Los resultados permiten estimar que para identificar suelos salinos en la zona de estudio (CEe > 4 dS/m), se debería alcanzar (dS/m): CE1:1m/v > 2,35; CE1:2,5m/v > 1,20; CE1:5m/v > 0,72;CE1:1v/v > 2,27; CE1:2,5v/v > 1,28; CE1:5v/v > 0,74; CE1:1v/v is > 2,48; CE1:2,5v/v is > 1,33 y CE1:5v/v is > 0,74. Finalmente, de las variables seleccionadas por el análisis de regresión múltiple paso a paso, el limo es la que se repite en todos los modelos con signo negativo, seguido del pH de la suspensión suelo:agua (1:1m/v; 1:2,5m/v y 1:2,5v/v; 1:5v/v) y también con signo negativo. Indicando las variables regresoras que mejor explican los modelos.es_ES
Abstractdc.description.abstractAs an alternative to measuring the electrical conductivity of the saturated paste extract (ECe), the electrical conductivity (EC) in suspensions was measured, with three different soil:water ratios and 5 repetitions, in seven soils in Central Chile (four Mollisols, two Vertisols and one Entisol). The relationships between the ECe and the EC in soil:water solutions were evaluated on mass/volume and volume/volume basis at laboratory (EC1:1 m/v, EC1:2.5 m/v, EC1:5 m/v, EC1:1 v/v, EC1:2.5v/v, EC1:5v/v,), as well as volume/volume in the field or in situ (EC1:1 v/v is, EC1:2.5 v/v is, EC1:5 v/v is). The relationship between the different measured EC and some soil properties (texture, pH, water content at saturation, at 33, and at 1500 kPa) was also evaluated. The results allow estimating that to identify saline soils in the study area (ECe > 4 dS/m), the following should be reached (dS/m): EC1:1m/v > 2.35, EC1: 2,5m/v > 1,20, CE1:5m/v > 0,72, CE1:1v/v > 2,27, CE1:2,5v/v > 1,28, CE1:5v/v > 0,74, CE1:1v/v is > 2,48, CE1:2,5v/v is > 1,33 and CE1:5v/v is > 0,74. Finally, of the variables selected by the stepwise regression analysis, the silt is the most selected in all the models with a negative sign, followed by the pH of the soil:water suspension (1:1m/v; 1:2,5m/v and 1:2,5v/v; 1:5v/v) and also with a negative sign. Indicating the regressor variables that best explain the models.es_ES
Lenguagedc.language.isoeses_ES
Publisherdc.publisherUniversidad de Chilees_ES
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States*
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
Keywordsdc.subjectSalinidad de sueloes_ES
Keywordsdc.subjectMediciones in situ y laboratorioes_ES
Keywordsdc.subjectEcuaciones de regresión paso a pasoes_ES
Keywordsdc.subjectSoil salinityes_ES
Keywordsdc.subjectIn situ and laboratory measurementses_ES
Keywordsdc.subjectStepwise regression equationses_ES
Títulodc.titleRelaciones entre conductividad eléctrica en pasta saturada y en distintas suspensiones suelo: agua. Zona Central de Chilees_ES
Title in another languagedc.title.alternativeRelationships among electrical conductivity in saturated paste and in different soil: water suspensions: Central Zone of Chilees_ES
Document typedc.typeTesises_ES
dc.description.versiondc.description.versionVersión original del autores_ES
dcterms.accessRightsdcterms.accessRightsAcceso abiertoes_ES
Catalogueruchile.catalogadordeaes_ES
Departmentuchile.departamentoEscuela de Postgradoes_ES
Facultyuchile.facultadFacultad de Ciencias Agronómicases_ES
uchile.gradoacademicouchile.gradoacademicoMagisteres_ES
uchile.notadetesisuchile.notadetesisActividad Formativa Equivalente a Tesis para optar al grado de Magíster en Manejo de Suelos y Aguases_ES


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States