Mostrar el registro sencillo del ítem
Relaciones entre conductividad eléctrica en pasta saturada y en distintas suspensiones suelo: agua. Zona Central de Chile
Profesor guía | dc.contributor.advisor | Casanova Pinto, Manuel Antonio | |
Profesor guía | dc.contributor.advisor | Tapia Fernández, Yasna Mariela | |
Autor | dc.contributor.author | Bautista Mamani, Juan Elmer | |
Profesor colaborador | dc.contributor.other | Pfeiffer Jakob, Marco Matías | |
Profesor colaborador | dc.contributor.other | Salazar Guerrero, Osvaldo Alejandro | |
Fecha ingreso | dc.date.accessioned | 2024-08-19T19:31:08Z | |
Fecha disponible | dc.date.available | 2024-08-19T19:31:08Z | |
Fecha de publicación | dc.date.issued | 2020 | |
Identificador | dc.identifier.uri | https://repositorio.uchile.cl/handle/2250/200307 | |
Resumen | dc.description.abstract | Como alternativa a la medición de la conductividad eléctrica del extracto de pasta saturada (CEe), se midió la conductividad eléctrica (CE) en suspensiones, con 5 repeticiones y distintas relaciones suelo:agua, en siete suelos de Chile Central (cuatro Mollisoles, dos Vertisoles y un Entisol). Se evaluaron las relaciones entre la CEe y la CE en soluciones suelo:agua en base masa/volumen y volumen/volumen en laboratorio (CE1:1 m/v, CE1:2,5 m/v, CE1:5 m/v, CE1:1 v/v, CE1:2,5v/v, CE1:5v/v,), así como también volumen/volumen en terreno o in situ (CE1:1 v/v is, CE1:2,5 v/v is, CE1:5 v/v is). Se evaluó también la relación entre las distintas CE medidas y algunas propiedades de los suelos (textura, pH, contenido de agua a saturación, a 33 y a 1500 kPa). Los resultados permiten estimar que para identificar suelos salinos en la zona de estudio (CEe > 4 dS/m), se debería alcanzar (dS/m): CE1:1m/v > 2,35; CE1:2,5m/v > 1,20; CE1:5m/v > 0,72;CE1:1v/v > 2,27; CE1:2,5v/v > 1,28; CE1:5v/v > 0,74; CE1:1v/v is > 2,48; CE1:2,5v/v is > 1,33 y CE1:5v/v is > 0,74. Finalmente, de las variables seleccionadas por el análisis de regresión múltiple paso a paso, el limo es la que se repite en todos los modelos con signo negativo, seguido del pH de la suspensión suelo:agua (1:1m/v; 1:2,5m/v y 1:2,5v/v; 1:5v/v) y también con signo negativo. Indicando las variables regresoras que mejor explican los modelos. | es_ES |
Resumen | dc.description.abstract | As an alternative to measuring the electrical conductivity of the saturated paste extract (ECe), the electrical conductivity (EC) in suspensions was measured, with three different soil:water ratios and 5 repetitions, in seven soils in Central Chile (four Mollisols, two Vertisols and one Entisol). The relationships between the ECe and the EC in soil:water solutions were evaluated on mass/volume and volume/volume basis at laboratory (EC1:1 m/v, EC1:2.5 m/v, EC1:5 m/v, EC1:1 v/v, EC1:2.5v/v, EC1:5v/v,), as well as volume/volume in the field or in situ (EC1:1 v/v is, EC1:2.5 v/v is, EC1:5 v/v is). The relationship between the different measured EC and some soil properties (texture, pH, water content at saturation, at 33, and at 1500 kPa) was also evaluated. The results allow estimating that to identify saline soils in the study area (ECe > 4 dS/m), the following should be reached (dS/m): EC1:1m/v > 2.35, EC1: 2,5m/v > 1,20, CE1:5m/v > 0,72, CE1:1v/v > 2,27, CE1:2,5v/v > 1,28, CE1:5v/v > 0,74, CE1:1v/v is > 2,48, CE1:2,5v/v is > 1,33 and CE1:5v/v is > 0,74. Finally, of the variables selected by the stepwise regression analysis, the silt is the most selected in all the models with a negative sign, followed by the pH of the soil:water suspension (1:1m/v; 1:2,5m/v and 1:2,5v/v; 1:5v/v) and also with a negative sign. Indicating the regressor variables that best explain the models. | es_ES |
Idioma | dc.language.iso | es | es_ES |
Publicador | dc.publisher | Universidad de Chile | es_ES |
Tipo de licencia | dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | * |
Link a Licencia | dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
Palabras claves | dc.subject | Salinidad de suelo | es_ES |
Palabras claves | dc.subject | Mediciones in situ y laboratorio | es_ES |
Palabras claves | dc.subject | Ecuaciones de regresión paso a paso | es_ES |
Palabras claves | dc.subject | Soil salinity | es_ES |
Palabras claves | dc.subject | In situ and laboratory measurements | es_ES |
Palabras claves | dc.subject | Stepwise regression equations | es_ES |
Título | dc.title | Relaciones entre conductividad eléctrica en pasta saturada y en distintas suspensiones suelo: agua. Zona Central de Chile | es_ES |
Titulo en otro idioma | dc.title.alternative | Relationships among electrical conductivity in saturated paste and in different soil: water suspensions: Central Zone of Chile | es_ES |
Tipo de documento | dc.type | Tesis | es_ES |
dc.description.version | dc.description.version | Versión original del autor | es_ES |
dcterms.accessRights | dcterms.accessRights | Acceso abierto | es_ES |
Catalogador | uchile.catalogador | dea | es_ES |
Departamento | uchile.departamento | Escuela de Postgrado | es_ES |
Facultad | uchile.facultad | Facultad de Ciencias Agronómicas | es_ES |
uchile.gradoacademico | uchile.gradoacademico | Magister | es_ES |
uchile.notadetesis | uchile.notadetesis | Actividad Formativa Equivalente a Tesis para optar al grado de Magíster en Manejo de Suelos y Aguas | es_ES |
Descargar archivo
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Tesis Postgrado
Tesis Postgrado