Show simple item record

Authordc.contributor.authorLorca, 
Authordc.contributor.authorChild, 
Authordc.contributor.authorGarcía García, Patricio Andrés 
Authordc.contributor.authorSilva Silva, Laura 
Authordc.contributor.authorMartínez Martínez, Regina 
Authordc.contributor.authorJerez, Sofía 
Authordc.contributor.authorToledo Toledo, Gladys Luisa 
Authordc.contributor.authorMezzano, 
Admission datedc.date.accessioned2019-01-29T15:50:01Z
Available datedc.date.available2019-01-29T15:50:01Z
Publication datedc.date.issued1994
Cita de ítemdc.identifier.citationRevista medica de Chile, Volumen 122, Issue 8, 2018, Pages 925-931
Identifierdc.identifier.issn00349887
Identifierdc.identifier.urihttps://repositorio.uchile.cl/handle/2250/162523
Abstractdc.description.abstractAiming to study the applicability and reproducibility of four commercial kits used for the serological detection of Chagas disease (Chagatest-Inst Invest Paraguay, Ortho Chagas, Abbott Chagas (ELISA tests) and Estabilgen Hemo Chagas (indirect hemagglutination test)), a comparative serological study was performed in 256 sera samples coming from a highly endemic area, 249 samples from a low endemic area, 180 reference sera and 2264 samples coming from three blood banks. Specificity of the kits was excellent and sensitivity ranged from 60 to 100%. The indirect hemagglutination test has the lower sensitivity. Some disagreements in the results were observed in the three blood banks, probably due to an unsatisfactory reactive management. We conclude that ELISA tests should be recommended for routine detection of Chagas disease and that for this purpose, a net of laboratories under the direction of a national reference center should exist. This center should assess new commercial products, tr
Lenguagedc.language.isoen
Type of licensedc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile
Link to Licensedc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/
Sourcedc.sourceRevista medica de Chile
Keywordsdc.subjectMedicine (all)
Títulodc.titleEvaluation of commercial kits used for Chagas disease diagnosis in blood banks in Chile. II. Routine application Evaluación de reactivos comerciales empleados en el diagnostico de la enfermedad de Chagas en bancos de sangre de Chile. II. Aplicación rutina
Document typedc.typeArtículo de revista
Catalogueruchile.catalogadorSCOPUS
Indexationuchile.indexArtículo de publicación SCOPUS
uchile.cosechauchile.cosechaSI


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Chile
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Chile