About
Contact
Help
Sending publications
How to publish
Advanced Search
View Item 
  •   Home
  • Facultad de Ciencias Agronómicas
  • Tesis Pregrado
  • View Item
  •   Home
  • Facultad de Ciencias Agronómicas
  • Tesis Pregrado
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Browse byCommunities and CollectionsDateAuthorsTitlesSubjectsThis CollectionDateAuthorsTitlesSubjects

My Account

Login to my accountRegister
Biblioteca Digital - Universidad de Chile
Revistas Chilenas
Repositorios Latinoamericanos
Tesis LatinoAmericanas
Tesis chilenas
Related linksRegistry of Open Access RepositoriesOpenDOARGoogle scholarCOREBASE
My Account
Login to my accountRegister

Aplicación del modelo ISC-AERMOD para la estimación de dispersión de olores : caso estudio planta de tratamiento de aguas servidas La Farfana

Tesis
Thumbnail
Open/Download
IconMemoria_MaritzaBarrera.pdf (2.125Mb)
Publication date
2010
Metadata
Show full item record
Cómo citar
Morales S., Luis
Cómo citar
Aplicación del modelo ISC-AERMOD para la estimación de dispersión de olores : caso estudio planta de tratamiento de aguas servidas La Farfana
.
Copiar
Cerrar

Author
  • Barrera Curihuentro, Maritza Carolina;
Professor Advisor
  • Morales S., Luis;
Abstract
El funcionamiento de las Plantas de Tratamiento de Aguas Servidas (PTAS) provoca la emisión a la atmósfera de gases odorantes, que podrían afectar a las comunidades vecinas a éstas. Por ello, en el presente estudio se aplicó el modelo gaussiano de dispersión atmosférica ISC AERMOD para la simulación de olores, en base a las unidades de olor europeas definidas en la Norma Europea EN 13725:2003, a fin de evaluar eventos de olores en comunidades cercanas a la Planta de Tratamiento de Aguas Servidas La Farfana. Se trabajó con datos meteorológicos como dirección y velocidad de vientos, radiación global, temperatura, humedad relativa, precipitación, presión atmosférica, cobertura y altura de nubes. Además, de características topográficas representado por un Modelo Digital de Elevación de la zona y las características de las fuentes. En tanto, la cuantificación de las tasas emisiones de olor de las fuentes fue estimada a través de la técnica de olfatometría dinámica. Los resultados del modelo fueron comparados con mediciones en terreno de tipo sensorial (paneles de olor y monitoreo continuo). Estas simulaciones concordaron con ambas mediciones en terreno, generando mapas de olores entre las concentraciones de olores y los principales puntos receptores. Del mismo modo, la modelación se comparó con normativa internacional de países como Holanda, Alemania, Bélgica, España, entre otros; debido a la ausencia de normativa en Chile. Finalmente, se concluyó que la medición de emisiones de olor a través de olfatometría dinámica y el posterior uso de modelos de dispersión para la medición de la concentración del olor son herramientas eficaces para la realización de un estudio de olores en una zona en particular.
 
Wastewater treatment plants (PTWW) emit to the atmosphere, odorant gases that could affect the communities near them. This study was carried out to see how wastewater treatment plants affect the communities applying the Gaussian atmospheric dispersion modelling ISC AEROMOD for odour simulation, based on European odour units defined in the European norm EN 13725:2003 to evaluate odour situations in the communities near La Farfana wastewater treatment plant. The data considered for this study case was: meteorological weather such as wind speed and wind direction, global radiation, temperature, relative humidity, precipitation, atmospheric pressure, cloud cover and cloud height. Besides topographic characteristics represented by the Digital Elevation Model of the area and the characteristics of the sources. On the other hand, the quantification of the odour emission sources was calculated through the dynamic olfactometry technique. The results of the model were compared with measurements of sensorial type in the field (odour panels and continuous monitoring). These simulations agreed with both measurements in field, generating odour maps between odour concentration and the main receptive points. In the same way, the model was compared with the international norm in countries like Holland, Germany, Belgium, and Spain among others due to the lack of an odour norm in Chile. Finally, it was concluded that the measurement of odour emission through the dynamic olfactometry technique and later use of dispersion models to measure the concentration of odour are effective tools to carry out a research on odour in a particular area.
 
General note
Memoria para optar al Título Profesional de Ingeniero en Recursos Naturales Renovables
Identifier
URI: https://repositorio.uchile.cl/handle/2250/112443
Collections
  • Tesis Pregrado
xmlui.footer.title
31 participating institutions
More than 73,000 publications
More than 110,000 topics
More than 75,000 authors
Published in the repository
  • How to publish
  • Definitions
  • Copyright
  • Frequent questions
Documents
  • Dating Guide
  • Thesis authorization
  • Document authorization
  • How to prepare a thesis (PDF)
Services
  • Digital library
  • Chilean academic journals portal
  • Latin American Repository Network
  • Latin American theses
  • Chilean theses
Dirección de Servicios de Información y Bibliotecas (SISIB)
Universidad de Chile

© 2020 DSpace
  • Access my account